Dw-K1100f Distillation Titration Kjeldahl Nitrogen Protein Automatic Kjeldahl Analyzer Kjeldahl Apparatus

Product Details
Customization: Available
After-sales Service: Online Service
Warranty: 1 Year
Still deciding? Get samples of US$ 12800/Piece
Request Sample
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001
Export Year
2014-03-18
  • Dw-K1100f Distillation Titration Kjeldahl Nitrogen Protein Automatic Kjeldahl Analyzer Kjeldahl Apparatus
  • Dw-K1100f Distillation Titration Kjeldahl Nitrogen Protein Automatic Kjeldahl Analyzer Kjeldahl Apparatus
  • Dw-K1100f Distillation Titration Kjeldahl Nitrogen Protein Automatic Kjeldahl Analyzer Kjeldahl Apparatus
  • Dw-K1100f Distillation Titration Kjeldahl Nitrogen Protein Automatic Kjeldahl Analyzer Kjeldahl Apparatus
  • Dw-K1100f Distillation Titration Kjeldahl Nitrogen Protein Automatic Kjeldahl Analyzer Kjeldahl Apparatus
  • Dw-K1100f Distillation Titration Kjeldahl Nitrogen Protein Automatic Kjeldahl Analyzer Kjeldahl Apparatus
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Certifications
Overview

Basic Info.

Model NO.
DW-K1100F
Measuring Range
0.1mg -200mg N
Analysis Time
5-10min/Sample
Rsd
Average Value Relative Error ±0.5%
Recovery
≧99.5%
Burette Volume
1.0μl/Step
Sample Capacity
Solid≤5g/Sample, Liquid≤20ml/Sample
Water Consumption in The Distillation Pr
1.5L/Min
Data Storage Capacity
Dw-K1100f: 1800 Groups
Interface
USB, LAN, RS232, Can, WiFi
Power Supply
220VAC±10%, 50Hz
Power
2kw
Net Weight
38kg
Dimensions
455mm×391mm×730mm
Transport Package
455mm× 391mm× 730mm
Specification
455mm× 391mm× 730mm
Trademark
Drawell
Origin
Chongqing, China
HS Code
8419899090
Production Capacity
1000pieces/Month

Product Description

Product Description

Automatic Kjeldahl Analyzer

DW-K1100F

DW-K1100F Automatic Kjeldahl Analyzer is an automatic device integrating distillation and titration functions designed based on classic Kjeldahl nitrogen determination method. It's equipped with the latest core control system, powerful automatic degree and high-quality components, can easily achieve automatic waste discharge and cleaning of digestion waste discharge and cleaning of digestion tubes and titration cups, control steam supply and have real-time detection of condensation temperature. High-accuracy charging pump and titration system ensure test results accuracy, and multiple fluid level detection gives smooth test process.

DW-K1100F is automatic Kjeldahl analyzer, consist of distillation, titration, calculation, data treatment. The differences between two models: DW-K1100F adopt 300ml digestion tube, available titration while distillation; better ARM operation system and more methods editing.

Features
  1. High accuracy dozing and working: adopt 4 KNF pumps work for dozing, measurement liquid volume.
  2. Complete compatible design: Using 300mL tubes(φ42mm), compatible with con-generic products perfectly
  3. Easy Maintenance: Pre-install full functions of cleaning, include Digestion tube cleaning, Receiving cup cleaning, Alkali pipeline cleaning, Boric acid pipeline  cleaning, acid washing, steam bottle evacuation. Support customer make the routine maintenance easily.
  4. Highest titration accuracy, up to 1.0μL/step.

Characteristic
  1. Automatic waste discharge and cleaning ensure operator safety and save time.
  2. External titration cup design gives operator real-time control of the whole test pro
  3. cess.Steam flow is controllable, satisfying different test requirements.
  4. Regent barrel enjoys fluid absence warning function, ensuring smooth test going.
  5. High-precision charging pump and titration ensure test results accuracy.
  6. The temperature of distilled liquid is detected real time. If the temperature of distilled liquid is abnormal, to ensure the accuracy of experiment's result, instrument will stop working.
  7. Double distillation model is used to meet different experiments, to retard the speed of acid-base reaction.
  8. Digestion tube fast drain function is used to avoid operator touch distilled hot reagents, protecting operators.
  9. USB or RS485 interface is optional for PC connection.
Specification:
Measuring range 0.1mg ~200mg N
Analysis time 5~10min/sample
Reproducibility Average value relative error ±0.5%
Recovery >=99.5%
Burette volume 1.0μL/step
Sample capacity solid<=5g/sample, liquid<=20mL/sample
Water consumption in the distillation process 1.5L/min
Data storage capacity DW-K1100F: 1800 groups
Power supply 220VAC±10%, 50Hz
Power 2Kw
Net weight 38Kg
Dimensions 455mm×391mm×730mm
Detailed Photos

Dw-K1100f Distillation Titration Kjeldahl Nitrogen Protein Automatic Kjeldahl Analyzer Kjeldahl ApparatusDw-K1100f Distillation Titration Kjeldahl Nitrogen Protein Automatic Kjeldahl Analyzer Kjeldahl ApparatusDw-K1100f Distillation Titration Kjeldahl Nitrogen Protein Automatic Kjeldahl Analyzer Kjeldahl ApparatusDw-K1100f Distillation Titration Kjeldahl Nitrogen Protein Automatic Kjeldahl Analyzer Kjeldahl Apparatus

Certifications

Dw-K1100f Distillation Titration Kjeldahl Nitrogen Protein Automatic Kjeldahl Analyzer Kjeldahl ApparatusDw-K1100f Distillation Titration Kjeldahl Nitrogen Protein Automatic Kjeldahl Analyzer Kjeldahl Apparatus

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier