Product Description
Energy Dispersion X-ray Fluorescence Spectrometer
(DW-NP-5010)
Working principle
The original X-ray produced by X-ray tube and high voltage is irradiated on the sample after being properly filtered by the optical filter. The characteristic X-ray (called X-ray fluorescence) of the elements contained in the sample is stimulated. X-ray fluorescence spectra were obtained by using X-ray detectors with high energy resolution. Different elements formed different spectral peaks on the spectra.The strength of the spectral peak is directly proportional to the content of elements in the sample. The energy spectrum detected by the detector is analyzed by the computer. The types of elements contained in the sample are qualitatively analyzed by the position and shape of the spectral peak.
Application
DW-NP-5010A energy dispersive X-ray fluorescence spectrometer (XRF) is widely used in environmental protection, geology, mineral, metallurgy, cement, electronics, petrochemical, polymer, food, medicine and high-tech materials and other fields, playing an important role in product research and development, production process monitoring and quality management.In addition, the instrument can be used in archaeology, building materials, RoHS directive and other industries. It is the enterprise quality control ideal choice.
Model |
DW-NP-5010A |
Analysis principle |
Energy dispersive X-ray fluorescence analysis |
Element measuring range |
Any element from Na(11)-U(92) |
Min. measuring limit |
Cd/Hg/Br/Cr/Pb≤2 ppm |
Sample shape |
Arbitrary size, any irregular shape |
Sample type |
Plastic/metal/film/powder/liquid etc |
X ray tube
|
Target material |
Mo |
Tube voltage |
5─50KV |
Tube current |
1─1000uA |
Sample exposure diameter |
2, 5, 8mm |
Detector |
Si-PIN or SDD detector, high speed pulse height analysis system |
High voltage generator |
Special HV generator for X fluorescence |
ADC |
2048 channels |
Filter |
6 filters are automatically selected and converted. |
Sample observation |
200×color CCDcamera |
Analysis software |
Patented software products, free upgrade for life |
Analysis method |
Theoretical α coefficient method,basic parameter method, empirical coefficient method |
Analysis time |
30-900seconds, adjustable |
Operating system software |
WINDOWS XP |
Dataprocessing system
|
Host |
PC business model |
CPU |
≥2.8G |
Memory |
≥2g |
CD-ROM |
8xDVD |
Hard disk |
≥500G |
Display |
22'' or 24'' LCD display |
Working environment |
Temperature 10-35С,humidity 30-70%RH |
Detailed Photos
Certifications
FAQ