Drawell Laboratory Gc-1120 Gas Chromatograph Gc Machine Gas Chromatograph Analyzer with Chromatography Column Gcms Lcmsms Gcmsms Gas Analyzer Detector HPLC

Product Details
Customization: Available
After-sales Service: Online Technical Support
Warranty: 1 Year
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001
Export Year
2014-03-18
  • Drawell Laboratory Gc-1120 Gas Chromatograph Gc Machine Gas Chromatograph Analyzer with Chromatography Column Gcms Lcmsms Gcmsms Gas Analyzer Detector HPLC
  • Drawell Laboratory Gc-1120 Gas Chromatograph Gc Machine Gas Chromatograph Analyzer with Chromatography Column Gcms Lcmsms Gcmsms Gas Analyzer Detector HPLC
  • Drawell Laboratory Gc-1120 Gas Chromatograph Gc Machine Gas Chromatograph Analyzer with Chromatography Column Gcms Lcmsms Gcmsms Gas Analyzer Detector HPLC
  • Drawell Laboratory Gc-1120 Gas Chromatograph Gc Machine Gas Chromatograph Analyzer with Chromatography Column Gcms Lcmsms Gcmsms Gas Analyzer Detector HPLC
  • Drawell Laboratory Gc-1120 Gas Chromatograph Gc Machine Gas Chromatograph Analyzer with Chromatography Column Gcms Lcmsms Gcmsms Gas Analyzer Detector HPLC
  • Drawell Laboratory Gc-1120 Gas Chromatograph Gc Machine Gas Chromatograph Analyzer with Chromatography Column Gcms Lcmsms Gcmsms Gas Analyzer Detector HPLC
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
GC-1120
Appliance
Lab
Gaspath System
Single
Detector
FID
Energy Resolution
≤7.5%
Certification
CE, ISO
Stationary Phase
Solid Adsorbent
Mobile Phase
Gas
Chromatography Type
Gas Chromatography
Chromatographic Column Type
Capilary Column
Chromatographic Column Length
10~30cm
Chromatographic Column Diameter
20~40mm
Temperature Range
7degree-400degree
Program Ramps
7 Ramps in Total
Program Setting
0.1degree~40degree/Min
Total Time of Total Program
up to 655 Minutes
Brank
Drawell
Transport Package
Standard English Package
Specification
W450*D580*H(380+450) mm
Trademark
Drawell
Origin
China
HS Code
9027201100
Production Capacity
100pieces/Month

Packaging & Delivery

Package Size
89.00cm * 132.00cm * 111.00cm
Package Gross Weight
100.000kg

Product Description

Drawell Laboratory Gc-1120 Gas Chromatograph Gc Machine Gas Chromatograph Analyzer with Chromatography Column Gcms Lcmsms Gcmsms Gas Analyzer Detector HPLCDrawell Laboratory Gc-1120 Gas Chromatograph Gc Machine Gas Chromatograph Analyzer with Chromatography Column Gcms Lcmsms Gcmsms Gas Analyzer Detector HPLCDrawell Laboratory Gc-1120 Gas Chromatograph Gc Machine Gas Chromatograph Analyzer with Chromatography Column Gcms Lcmsms Gcmsms Gas Analyzer Detector HPLCDrawell Laboratory Gc-1120 Gas Chromatograph Gc Machine Gas Chromatograph Analyzer with Chromatography Column Gcms Lcmsms Gcmsms Gas Analyzer Detector HPLC
Product Description

DW-GC1120 GC Chromatography 

Features:
★Control system: designed for monitoring and controlling the instrument via the computer.
★Column Compartment/oven with superior thermal performance, multistage (10 ramps) programmed temperature control function. (supported by "control system")
★Advanced built-in data acquisition system , supporting real time instrument status monitoring, detection signal acquisition and PC control
★Column oven accommodates up to 3 chromatographic columns, and supports quick heat-up and rapid cool-down with automated back-door opening.
★Flexible sample introduction system: 3 sample injectors could be installed and operated simultaneously with independent temperature control.
★High sensibility and stability detector.
★2 independent and analog signals output.
★M6 software, compatible with GLP/FDA-21 CFR Part11 requirements and regulations. (electronic records and signatures)

Gas chromatography and accessories:
Carrier Gas System + Sample Introduction System + Separation System + Temperature Control System + Detector
Carrier Gas System: air source/ purification and desiccation device/ flow rate control device
Sample Introduction System: sample injector
Separation System: chromatographic column(packed column and capillary column)
Temperature Control System (Column Oven): constant temperature and programmed temperature
Detector: FID/ TCD/ FPD/ NPD

Advanced Microcomputer Control System:
★Superior performance with advanced, microcomputer-based temperature control system 
★High temperature accuracy (optimum ± 0.02ºC), high reliability, and anti-interference
★Self-diagnosis/ self-protection function (overheat protection, power-off protection, etc.)
★Intuitive display of timing program, detector status, measurement range, current setting, etc

Model#  GC1120
Sample Introduction System sample injector and evaporation chamber
Column Oven Temperature range Ambient temperature +7ºC ~ 400ºC  (in 1ºC increment)
Temperature accuracy  ± 0.02ºC
Cooling time 400ºC to 50ºC in 8-10 min at 25ºC ambient
Programmed temperature setting 0.1ºC~40ºC/min (in 1ºC increment)
Program ramps 7 ramps in total (10 ramps available with control workstation)
Size (L*W*H) 284*280*241mm(inside) 340*345*281mm(outside)
Flame Ionization Detector
(FID)
Detection limit ≤3×10-12g/s (C16) 
Best test result ≤3×10-12g/s (C16)
Drift ≤6×10-13A/30min
Noise ≤5×10-14A
Linearity range ≥106
Thermal Conductivity Detector
(TCD)
Sensitivity ≥5000mV, mL/mg (C16)
Baseline noise ≤20µV
Drift ≤60µV/h
Linearity range ≥104
Flame Photometric Detector
(FPD)
Detection limit ≤8×10-13g/s(P) ; ≤8×10-11g/s(S)
Drift ≤2×10-11A/30min
Baseline noise ≤5×10-12A
Nitrogen-Phosphorus Detector (NPD) Detection limit ≤5×10-12g/s(N)  (Azobenzene)
            
5×10-13g/s(P)  (Malathion)
Electron Capture Detector(ECD)  Linear range ≥10 3 (γ -666)
Baseline drift  ≤80μ V/h
Baseline noise ≤20μ V
Detection limit ≤2 X 10-13g/ml (γ -666)
 
Detailed Photos

 

Drawell Laboratory Gc-1120 Gas Chromatograph Gc Machine Gas Chromatograph Analyzer with Chromatography Column Gcms Lcmsms Gcmsms Gas Analyzer Detector HPLCDrawell Laboratory Gc-1120 Gas Chromatograph Gc Machine Gas Chromatograph Analyzer with Chromatography Column Gcms Lcmsms Gcmsms Gas Analyzer Detector HPLC

Company Profile

Drawell Laboratory Gc-1120 Gas Chromatograph Gc Machine Gas Chromatograph Analyzer with Chromatography Column Gcms Lcmsms Gcmsms Gas Analyzer Detector HPLCDrawell Laboratory Gc-1120 Gas Chromatograph Gc Machine Gas Chromatograph Analyzer with Chromatography Column Gcms Lcmsms Gcmsms Gas Analyzer Detector HPLC

FAQ

Drawell Laboratory Gc-1120 Gas Chromatograph Gc Machine Gas Chromatograph Analyzer with Chromatography Column Gcms Lcmsms Gcmsms Gas Analyzer Detector HPLC

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
People who viewed this also viewed