Dw-Gc1120 Microcomputer Control Gc Gas Chromatography Machine

Product Details
Customization: Available
After-sales Service: Online Technical Support
Warranty: 1 Year
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001
Export Year
2014-03-18
  • Dw-Gc1120 Microcomputer Control Gc Gas Chromatography Machine
  • Dw-Gc1120 Microcomputer Control Gc Gas Chromatography Machine
  • Dw-Gc1120 Microcomputer Control Gc Gas Chromatography Machine
  • Dw-Gc1120 Microcomputer Control Gc Gas Chromatography Machine
  • Dw-Gc1120 Microcomputer Control Gc Gas Chromatography Machine
  • Dw-Gc1120 Microcomputer Control Gc Gas Chromatography Machine
Find Similar Products
  • Overview
  • Product Feature
  • Technical Specification
  • Detailed Photos
  • Recommend Products
  • Company Profile
  • Why choose us
  • Our Service
  • FAQ
Overview

Basic Info.

Model NO.
DW-GC1120
Appliance
Lab
Gaspath System
Single
Detector
FID
Energy Resolution
≤7.5%
Certification
CE, ISO
Stationary Phase
Solid Adsorbent
Mobile Phase
Gas
Chromatography Type
Gas Chromatography
Chromatographic Column Type
Capilary Column
Temperature Range
7degree-400degree
Program Ramps
7 Ramps in Total
Program Setting
0.1degree~40degree/Min
Total Time of Total Program
up to 655 Minutes
Brank
Drawell
Transport Package
Standard English Package
Specification
W450*D580*H(380+450) mm
Trademark
Drawell
Origin
China
Production Capacity
100pieces/Month

Product Description

DW-GC1120 Microcomputer Control GC Gas Chromatography Machine
Dw-Gc1120 Microcomputer Control Gc Gas Chromatography Machine
Product Feature

Temperature Control :
Temperature Range:7ºC ~ 400ºC above room temperature, (increment 1ºC)
Temperature Control Object:Column Box, front and back detector, front and back sampler, assist,total six channels.
Program ramps : 7 ramps in total
Program setting:0.1ºC~40ºC/min(increment 0.1ºC)
Total time of total program : Up to 655 minutes, (increment 0.1ºC)

Hydrogen flame ionization detector (FID):
Minimum detectable quantity: M≤8×10-12g/s (C16)
Best test result: M≤3×10-12g/s (C16)
Noise: ≤5×10-14A
Drift: ≤6×10-13A/h
Linearity range: ≥106

Thermal conductivity detector(TCD):
Sensitivity:≥5000mV.mL/mg (C16)
Noise: ≤20µV
Drif: ≤30µV/h
Linearity rang: ≥104

High Sensitivity Thermal conductivity detector(HTCD):
Sensitivity: ≥10000mV.mL/mg (C16)

Electron capture detector(ECD):
Detectability: ≤1×10-13g/s  (γ-666)
Linearity range: ≥103
Maximum using temperature:  350ºC

Flame photometric detector(FPD):
Detectability: ≤2×10-11g/s(P)  (Parathion-methyl)
                       ≤1×10-10g/s(S)  (Parathion-methyl)

Nitrogen-phosphorus detector(NPD):
Detectability: ≤5×10-12g/s(N)  (Azobenzene)
                     ≤5×10-13g/s(P)  (Malathion)  (On programmed)

Photoelectric ion detector(PID):
Detectability: ≤1ppb             (Benzene)

Technical Specification
Flexible Sample Introduction System
Up to three injectors may be installed and operated simultaneously with independent temperature control. Wide range of injectors is available to be chosen from for various applications. It is very convenient for installation and disassembly of sample injectors.
Sample Injector with Mono Packed Column/Double Packed Columns:
Several alternative sample introduction methods, including on-column sample introduction and six-way valve injection;
Adapter for injection to capillary column (0.53 mm i.d.).
Sample injector for capillary column
Special sample injector with septum purge and back-pressure valve splitting;
Special programmable split/splitless injector with solenoid valve, septum purge, back-pressure valve splitting, and standalone carrier gas and make-up gas flow;
Modified dual-packed-column sample injector for injection to capillary column by employing some connectors and back-pressure valve splitting.

Advanced Pneumatics
Carrier gas control with constant pressure valve and constant flow valve;
Air and hydrogen control with constant pressure valve and needle valve;
Flow easily adjustable through constant flow valve and needle valve with digital display;
High precision, reproducibility and reliability.

Sensitive and reliable detector
Up to three detectors (FID, TCD, ECD, etc) may be installed and operated simultaneously. Simultaneous multi-detection with detectors in series or in parallel meets the various analysis requirements.
The new FID provides higher sensitivity than ever before. It is very convenient to disassemble and clean the jet and collector. Precisely fixed emitter configuration ensures conformity of product performance;
Excellent TCD detector with high-resistance tungsten-rhenium filaments provides high sensitivity. A sensitivity of 10000 mV·mL/mg is achieved with optional amplifier circuit board. Special configuration of air heat insulation enhances the stability of TCD detector
Constant-current, pulse-modulated ECD detector sets sensitivity and current by computer.

 
Detailed Photos

Dw-Gc1120 Microcomputer Control Gc Gas Chromatography MachineDw-Gc1120 Microcomputer Control Gc Gas Chromatography MachineDw-Gc1120 Microcomputer Control Gc Gas Chromatography MachineDw-Gc1120 Microcomputer Control Gc Gas Chromatography MachineDw-Gc1120 Microcomputer Control Gc Gas Chromatography Machine

Recommend Products

Dw-Gc1120 Microcomputer Control Gc Gas Chromatography Machine

Company Profile

Dw-Gc1120 Microcomputer Control Gc Gas Chromatography Machine

Why choose us
Dw-Gc1120 Microcomputer Control Gc Gas Chromatography Machine
Our Service
Dw-Gc1120 Microcomputer Control Gc Gas Chromatography MachineDw-Gc1120 Microcomputer Control Gc Gas Chromatography Machine
FAQ
Dw-Gc1120 Microcomputer Control Gc Gas Chromatography Machine

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier