• Dw-AA4530f Metal Analysis Graphite Furnace Flame Fouble Beam Atomic Absorption Spectrometer
  • Dw-AA4530f Metal Analysis Graphite Furnace Flame Fouble Beam Atomic Absorption Spectrometer
  • Dw-AA4530f Metal Analysis Graphite Furnace Flame Fouble Beam Atomic Absorption Spectrometer
  • Dw-AA4530f Metal Analysis Graphite Furnace Flame Fouble Beam Atomic Absorption Spectrometer
  • Dw-AA4530f Metal Analysis Graphite Furnace Flame Fouble Beam Atomic Absorption Spectrometer
  • Dw-AA4530f Metal Analysis Graphite Furnace Flame Fouble Beam Atomic Absorption Spectrometer

Dw-AA4530f Metal Analysis Graphite Furnace Flame Fouble Beam Atomic Absorption Spectrometer

After-sales Service: Online Technical Support
Application: Laboratory Apparatus
Warranty: 1 Year
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Dw-AA4530f Metal Analysis Graphite Furnace Flame Fouble Beam Atomic Absorption Spectrometer pictures & photos
Dw-AA4530f Metal Analysis Graphite Furnace Flame Fouble Beam Atomic Absorption Spectrometer
US $6,900-17,000 / Set
Min. Order: 1 Set
Diamond Member Since 2020

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Manufacturer/Factory, Trading Company
  • Overview
  • Product Feature
  • Technical Specification
  • Detailed Photos
  • Company Profile
  • Why choose us
  • Our Service
  • FAQ
Overview

Basic Info.

Model NO.
DW-AA4530F
Detection Method
Spectrophotometer
Advantage
High Sensitive
Principle
Classic Spectrometer
Wavelengths
UV Spectrometer
Dispersive Element
Interferometer Spectrometer
Light Number
Monochromator
Certification
CE
Customized
Customized
Wl Range (Nm)
190-900
Spectrum Bandwidth
0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm
Background Calibration Ability
Greater Than 30 Times
RS232
Including
Brand
Drawell
Transport Package
Standard English Package
Specification
125*80*75cm
Trademark
Drawell
Origin
China
Production Capacity
20pieces/Month

Product Description

DW-AA4530F Metal Analysis Graphite Furnace Flame Fouble Beam Atomic Absorption Spectrometer
 
Product Feature
CHARACTERISTICS
1. Completely controlled by PC, can flexibly select the flame and graphite furnace atomizer (optional).
2. Integrated floated optical platform design can obviously improve the optical system shock resistance and keep stable though use the optical signal for a long term.
3. Eight light stands can be changed automatically and preheat the eight lights meantime as well as optimize
the working condition of the hollow cathode lamp.
4. Position adjusting: the best height of the flame burner and can automatically set the front and rear positions.
5. Fully automated wavelength scanning and peak searching.
6. Complete safety chains protection equipment: the function of warning and automatic safety protection towards the wrong burner, leakage of the gas, under voltage of air and the abnormal flameout.
7. Deuterium lamp and self-absorption background regulation.
8. Data processing: super strong database, possesses more than 500 data self-storage and cut-off storage function, can store the analyzed result with the form of EXCEL and the testing method and the result can be randomly called.
9. Measuring method: flame absorption method and emission method.
10.Result printing: parameter printing, data result printing and diagram printing.

COMPLETE AUTOMATIC CONTROLLING SYSTEM
With the help of the software, the following can be easily achieved
1. Selection of the element lamp
2. Up-down-front-rear adjustment of the lifter
3. Adjustment of the optical energy
4. Selection of the slit
5. Determination of wavelength scanning and peak searching
6.  Selection of the atomizer
7. Setting of the background deduction method
8.  Controlling of the gas flow
9. Automatic flaming and flaming out
10.Setting of the graphite furnace testing method

 
Technical Specification
 
WL range (nm) 190-900
WL accuracy £ ±0.5nm
WL repeatability £ 0.3nm (single direction)
Spectrum bandwidth 0.1, 0.2, 0.4, 1.0 and 2.0nm
Resolution <40%
Base line stability ±0.004Abs/30min
Characteristic concentration of copper £ 0.04mg/ml/1%
Detection limit of copper £0.008mg/ml
Background calibration ability Greater than 30 times
RS232 including
Printer optional
Detailed Photos

Dw-AA4530f Metal Analysis Graphite Furnace Flame Fouble Beam Atomic Absorption SpectrometerDw-AA4530f Metal Analysis Graphite Furnace Flame Fouble Beam Atomic Absorption SpectrometerDw-AA4530f Metal Analysis Graphite Furnace Flame Fouble Beam Atomic Absorption SpectrometerDw-AA4530f Metal Analysis Graphite Furnace Flame Fouble Beam Atomic Absorption SpectrometerDw-AA4530f Metal Analysis Graphite Furnace Flame Fouble Beam Atomic Absorption SpectrometerDw-AA4530f Metal Analysis Graphite Furnace Flame Fouble Beam Atomic Absorption Spectrometer

Company Profile

Dw-AA4530f Metal Analysis Graphite Furnace Flame Fouble Beam Atomic Absorption Spectrometer

Why choose us
Dw-AA4530f Metal Analysis Graphite Furnace Flame Fouble Beam Atomic Absorption Spectrometer
Our Service
Dw-AA4530f Metal Analysis Graphite Furnace Flame Fouble Beam Atomic Absorption SpectrometerDw-AA4530f Metal Analysis Graphite Furnace Flame Fouble Beam Atomic Absorption Spectrometer
FAQ
Dw-AA4530f Metal Analysis Graphite Furnace Flame Fouble Beam Atomic Absorption Spectrometer

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Dw-AA4530f Metal Analysis Graphite Furnace Flame Fouble Beam Atomic Absorption Spectrometer pictures & photos
Dw-AA4530f Metal Analysis Graphite Furnace Flame Fouble Beam Atomic Absorption Spectrometer
US $6,900-17,000 / Set
Min. Order: 1 Set
Diamond Member Since 2020

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Manufacturer/Factory, Trading Company
Management System Certification
ISO 9001
Export Year
2014-03-18