Icp-Ms-2000 Heavy Metal Elements Analysis Inductively Coupled Plasma Mass Spectrophotometer Spectroscopy Spectrometry Spectrometer Icpms Icp Ms

Chongqing Drawell Instrument Co., Ltd.
  • Audited Supplier
  • 7 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • Wide Mass Range: Quality Quantity Range: 2-255 amu, covering most periodic table elements.
  • Advanced Ion Guide: High-efficiency hexapole ion guide system for optimal ion transmission.
  • ISO9001 & CE Certified: Meets national standards with ISO9001 and CE certifications.
  • Customizable Options: Product supports customized configurations for specific needs.
  • Automatic Tuning: Software provides automatic tuning for isotopic ratio and dilution.

Product Images of Icp-Ms-2000 Heavy Metal Elements Analysis Inductively Coupled Plasma Mass Spectrophotometer Spectroscopy Spectrometry Spectrometer Icpms Icp Ms

Icp-Ms-2000 Heavy Metal Elements Analysis Inductively Coupled Plasma Mass Spectrophotometer Spectroscopy Spectrometry Spectrometer Icpms Icp Ms
Icp-Ms-2000 Heavy Metal Elements Analysis Inductively Coupled Plasma Mass Spectrophotometer Spectroscopy Spectrometry Spectrometer Icpms Icp Ms pictures & photos
Icp-Ms-2000 Heavy Metal Elements Analysis Inductively Coupled Plasma Mass Spectrophotometer Spectroscopy Spectrometry Spectrometer Icpms Icp Ms
Icp-Ms-2000 Heavy Metal Elements Analysis Inductively Coupled Plasma Mass Spectrophotometer Spectroscopy Spectrometry Spectrometer Icpms Icp Ms pictures & photos
Icp-Ms-2000 Heavy Metal Elements Analysis Inductively Coupled Plasma Mass Spectrophotometer Spectroscopy Spectrometry Spectrometer Icpms Icp Ms
Icp-Ms-2000 Heavy Metal Elements Analysis Inductively Coupled Plasma Mass Spectrophotometer Spectroscopy Spectrometry Spectrometer Icpms Icp Ms pictures & photos
Icp-Ms-2000 Heavy Metal Elements Analysis Inductively Coupled Plasma Mass Spectrophotometer Spectroscopy Spectrometry Spectrometer Icpms Icp Ms
Icp-Ms-2000 Heavy Metal Elements Analysis Inductively Coupled Plasma Mass Spectrophotometer Spectroscopy Spectrometry Spectrometer Icpms Icp Ms pictures & photos
Icp-Ms-2000 Heavy Metal Elements Analysis Inductively Coupled Plasma Mass Spectrophotometer Spectroscopy Spectrometry Spectrometer Icpms Icp Ms
Icp-Ms-2000 Heavy Metal Elements Analysis Inductively Coupled Plasma Mass Spectrophotometer Spectroscopy Spectrometry Spectrometer Icpms Icp Ms pictures & photos
Icp-Ms-2000 Heavy Metal Elements Analysis Inductively Coupled Plasma Mass Spectrophotometer Spectroscopy Spectrometry Spectrometer Icpms Icp Ms
Icp-Ms-2000 Heavy Metal Elements Analysis Inductively Coupled Plasma Mass Spectrophotometer Spectroscopy Spectrometry Spectrometer Icpms Icp Ms pictures & photos
Icp-Ms-2000 Heavy Metal Elements Analysis Inductively Coupled Plasma Mass Spectrophotometer Spectroscopy Spectrometry Spectrometer Icpms Icp Ms
  • Icp-Ms-2000 Heavy Metal Elements Analysis Inductively Coupled Plasma Mass Spectrophotometer Spectroscopy Spectrometry Spectrometer Icpms Icp Ms
  • Icp-Ms-2000 Heavy Metal Elements Analysis Inductively Coupled Plasma Mass Spectrophotometer Spectroscopy Spectrometry Spectrometer Icpms Icp Ms
    Icp-Ms-2000 Heavy Metal Elements Analysis Inductively Coupled Plasma Mass Spectrophotometer Spectroscopy Spectrometry Spectrometer Icpms Icp Ms
  • Icp-Ms-2000 Heavy Metal Elements Analysis Inductively Coupled Plasma Mass Spectrophotometer Spectroscopy Spectrometry Spectrometer Icpms Icp Ms
    Icp-Ms-2000 Heavy Metal Elements Analysis Inductively Coupled Plasma Mass Spectrophotometer Spectroscopy Spectrometry Spectrometer Icpms Icp Ms
  • Icp-Ms-2000 Heavy Metal Elements Analysis Inductively Coupled Plasma Mass Spectrophotometer Spectroscopy Spectrometry Spectrometer Icpms Icp Ms
    Icp-Ms-2000 Heavy Metal Elements Analysis Inductively Coupled Plasma Mass Spectrophotometer Spectroscopy Spectrometry Spectrometer Icpms Icp Ms
  • Icp-Ms-2000 Heavy Metal Elements Analysis Inductively Coupled Plasma Mass Spectrophotometer Spectroscopy Spectrometry Spectrometer Icpms Icp Ms
    Icp-Ms-2000 Heavy Metal Elements Analysis Inductively Coupled Plasma Mass Spectrophotometer Spectroscopy Spectrometry Spectrometer Icpms Icp Ms
  • Icp-Ms-2000 Heavy Metal Elements Analysis Inductively Coupled Plasma Mass Spectrophotometer Spectroscopy Spectrometry Spectrometer Icpms Icp Ms
    Icp-Ms-2000 Heavy Metal Elements Analysis Inductively Coupled Plasma Mass Spectrophotometer Spectroscopy Spectrometry Spectrometer Icpms Icp Ms
  • Icp-Ms-2000 Heavy Metal Elements Analysis Inductively Coupled Plasma Mass Spectrophotometer Spectroscopy Spectrometry Spectrometer Icpms Icp Ms
    Icp-Ms-2000 Heavy Metal Elements Analysis Inductively Coupled Plasma Mass Spectrophotometer Spectroscopy Spectrometry Spectrometer Icpms Icp Ms

Find Similar Products

Product Description

Product Description

ICP-MS-2000 Inductively Coupled Plasma Mass Spectrometer


Introduction:
Inductively coupled plasma mass spectrometer ( abbreviated ICP-MS), was developed in the 1980s, a new micro ( 10-6 ) , trace ( 10-9 ) and ultra-trace ( 10-12 ) elemental analysis technology. Most of the periodic table of elements can be determined , very low detection limit , a very wide dynamic range , simple lines , less interference , high precision, fast speed , can provide isotopic analysis.

This product is the first domestic industrial inductively coupled plasma mass spectrometer , the instrument of the performance reached the national standard , to meet the needs of user applications , cost-effective ; the products are mainly used in environmental , food , semiconductor, medical and physiological analysis , nuclear industrial fields.

Features:
Injection System: open- injection system architecture, using nebulizer externally mounted , self-positioning, without adjustment .
Torch position adjustment system : full control of the computer x, y, z torch accurate three-dimensional position , all adjustment parameters stored in the analysis. Plasma shielding technology : greatly improved sensitivity , improve the detection limit of the number of elements of low quality , to ppt level
Activities valves: computer control, protection equipment vacuum , easy disassembly and cleaning sampling and skimmer cones work in the vacuum system .

Ion lens system : with a high efficiency hexapole ion guide system , ion transmission efficiency to get the best quality in the whole range of ion focusing automatic tuning process , the vacuum chamber of the lens using asymmetric installation , easy disassembly positioning.
Detector : ETP dual mode detector , without digital / analog switch .
The new vacuum chamber structure : the cavity without any wires , each component asymmetric installation and plug-in installation .
Power protection systems: power outage occurred in the accident , security itself off without damaging the instrument system .
Software: Provides automatic control instruments and their accessories abilities, software encompasses a variety of analytical methods, including special isotope ratio determination and isotope dilution method .


Technical parameters:
Quality Quantity Range : 2 ~ 255 amu
Measuring range : ≥108
Sensitivity : Be≥2 × 106; In≥35 × 106; U≥30 × 106 units (cps / mg / L)
The detection limit : Be≤10; In ≤2; U≤2 units (ng / L)
Resolution : 0.6 ~ 0.8 amu
SNR : ≥50 × 106
Background noise : ≤2 cps ( full mass range )

Mass axis stability : ≤0.05 amu / 24 h
Stability RSD: short-term ≤3%; long ≤4%
Oxide ions : CeO + / Ce + ≤3%
Bivalent ions : 69Ba2 + / 138Ba + ≤3%
Isotope ratio : (107Ag / 109Ag) ≤0.3%
Abundance sensitivity : ≤1 × 10-6 low quality end ; ≤5 × 10-7 high mass

Detailed Photos

Icp-Ms-2000 Heavy Metal Elements Analysis Inductively Coupled Plasma Mass Spectrophotometer Spectroscopy Spectrometry Spectrometer Icpms Icp Ms
Icp-Ms-2000 Heavy Metal Elements Analysis Inductively Coupled Plasma Mass Spectrophotometer Spectroscopy Spectrometry Spectrometer Icpms Icp MsIcp-Ms-2000 Heavy Metal Elements Analysis Inductively Coupled Plasma Mass Spectrophotometer Spectroscopy Spectrometry Spectrometer Icpms Icp MsIcp-Ms-2000 Heavy Metal Elements Analysis Inductively Coupled Plasma Mass Spectrophotometer Spectroscopy Spectrometry Spectrometer Icpms Icp MsIcp-Ms-2000 Heavy Metal Elements Analysis Inductively Coupled Plasma Mass Spectrophotometer Spectroscopy Spectrometry Spectrometer Icpms Icp Ms

Certifications

Icp-Ms-2000 Heavy Metal Elements Analysis Inductively Coupled Plasma Mass Spectrophotometer Spectroscopy Spectrometry Spectrometer Icpms Icp MsIcp-Ms-2000 Heavy Metal Elements Analysis Inductively Coupled Plasma Mass Spectrophotometer Spectroscopy Spectrometry Spectrometer Icpms Icp Ms

FAQ

Icp-Ms-2000 Heavy Metal Elements Analysis Inductively Coupled Plasma Mass Spectrophotometer Spectroscopy Spectrometry Spectrometer Icpms Icp Ms

About the Supplier

This supplier has been audited by SGS. Verify the report on the official SGS website with ID "QIP-ASR2391291". Items marked "verified" are certified.

Watch Video
Watch Video
Chongqing Drawell Instrument Co., Ltd.
Chongqing Drawell Instrument Co., Ltd.
Chongqing Drawell Instrument Co., Ltd.
Chongqing Drawell Instrument Co., Ltd.
Chongqing Drawell Instrument Co., Ltd.
Chongqing Drawell Instrument Co., Ltd.
Chongqing Drawell Instrument Co., Ltd.
Chongqing Drawell Instrument Co., Ltd.

About Our Factory & Business Background

Address
Room 2204, Building 11, No. 1 Shiyou Road, Yuzhong District, Chongqing, China
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram
International Commercial Terms(Incoterms)
FOB, EXW, CFR, CIF, DAT, FAS, DDP, DAP, CIP, CPT, FCA
Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays
Nearest Port
Shanghai, Guangzhou, Shenzhen and etc.

Our Production Capability & Technical Expertise

Main Products
Spectrophotometer/ Spectrometer, Autoclave, PCR, Chromatograph, Freezer, Incubator and Oven, Centrifuge, Microscope, Rotary Evaporator, Balance

Our Industry Experience & Global Business Record

Export Year
2014-03-18
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What is the mass range of the instrument?
The quality quantity range is 2-255 amu.
Is the product customizable?
Yes, the product is customized.
What certifications does the instrument have?
The instrument has ISO9001 and CE certifications.
What is the warranty period?
The warranty period is 1 year.
What is the after-sales service provided?
Online service is provided.
What is the lead time for delivery?
Peak season lead time is one month; off-season lead time is within 15 workdays.
What are the main applications for this spectrometer?
It is mainly used in environmental, food, semiconductor, medical, physiological, and nuclear industrial fields.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now