• Factory Price Liquid Chromatography LC Ms Mass Chromatography
  • Factory Price Liquid Chromatography LC Ms Mass Chromatography
  • Factory Price Liquid Chromatography LC Ms Mass Chromatography
  • Factory Price Liquid Chromatography LC Ms Mass Chromatography
  • Factory Price Liquid Chromatography LC Ms Mass Chromatography
  • Factory Price Liquid Chromatography LC Ms Mass Chromatography

Factory Price Liquid Chromatography LC Ms Mass Chromatography

After-sales Service: Free Online Technical Support
Warranty: One Year
Appliance: The Analysis of Environmental Samples
Energy Resolution: ≤7%
Certification: CE, ISO
Chromatography Type: Liquid Chromatography
Customization:
Diamond Member Since 2020

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
LC-MS-2000
Chromatographic Column Type
Convetional Analytical Column
Chromatographic Column Length
10~30cm
Mass Range
M/Z 10-2000amu
Resolution
Unit Mass Resolution 0.7amu (≤ 1 Amu)
Mass Accuracy
≤ ±0.2amu
Mass Axis Stability
≤ ± 0.2amu/12h
Scan Rate
1000amu/S in The Standard Mode, 10000amu/S in The
Signal to Noise Ratio (Snr)
Esi +, 10pg Reserpine, S/N ≥ 50:1(RMS)
Peak Area Repeatability
Rsd ≤ 4.6%
Retention Time Repeatability
Rsd ≤ 1.5%
Transport Package
Contact
Specification
Contact
Trademark
Drawell
Origin
China
Production Capacity
20 Per Month

Product Description

Product Description

 

Liquid Chromatography Mass Spectrometry (LC/MS)
LC-MS-2000


LC-MS-2000 meets every performance index specified in the related national regulations about the verification requirements.
The adoption of imported vacuum pumps with higher pumping speed has effectively reduced the chemical interference due to the background vacuum. A more compact structure design has successfully reduced one third of the instrument's whole width.


The core selling points of LC-MS-2000
  • The unique design of vortex gas heating at the ion source achieves an accurate control and
also a uniform distribution of the temperature.
  • Simultaneously acquiring data for analysis through multiple channels efficiently improves the analytical speed and the
following works.
  • A fast switch between positive and negative ionization modes supports flexible testing solutions.
The fastest switching time of HVPS can reach 20ms at the range of -10kV to +10kV.
  • The patented design of the hexapole ion guide can greatly improve the transmission of ions, especially of the ion
signals of high mass number.
  • Capability of obtaining abundant mass spectrum information, including molecular mass and multiple structural
information.
  • The software of ChemAnalyst can support a powerful performance of the instrument and ensure an easy operation of it
with a simple switch between Chinese and English user interfaces at one click.
  • Provision of various and flexible solutions by combining such different ion source configurations as ESI(standard),
APCI(optional), APPI(optional).
  • Operation of the auto-sampler through the software can effectively increase the sample
throughput and complete an unattended and automatic sequence detection.
  • Compliance with the requirements of GMP and GLP by adding a user authority management module, a data integrity
module, and an audit traceability module.
  • Test capability of mass range of 10-2000amu.
  • Having improved the service life, the dynamic range, and the sensitivity of the detector by a
wide margin.

Technical Parameters
 
Mass Range m/z 10-2000amu
Resolution  unit mass resolution 0.7amu (≤ 1 amu)
Mass Accuracy ≤ ±0.2amu (within the mass calibration range of the scan mode)
Mass Axis Stability ≤ ± 0.2amu/12h (under that condition of constant temperature ± 2ºC)
Scan Rate 1000amu/s in the standard mode, 10000amu/s in the fast scan mode
Signal to Noise Ratio (SNR) ESI +, 10pg reserpine, S/N ≥ 50:1(RMS)
Peak Area Repeatability RSD ≤ 4.6%
Retention Time Repeatability RSD ≤ 1.5%

Instrument Configuration



Sample Injection System
 
LC310 isocratic system (optional configuration),including LC pump, manual injection valve (six way injection valve 7725i ), column temperature box;
LC310 gradient system (optional configuration), including LC pumps (two pumps), high pressure gradient mixer, column temperature box, UV detector; 
Injection pump, which is integrated into the mass spectrometer (the injection speed can be adjusted in several stages, and the minimum injection speed is 1uL/min);
 Autosampler (optional configuration, up to 108 of 2mL vials);
Ion source vacuum interface and ion optical components ESI (standard),APCI(option) ;cone; hexapole
Mass analyzer and detector Quadrupole High energy dynode electron multiplier
Vacuum system 2 turbomolecular pumps with the pumping speed of 350L/s each;
1 mechanical pump with the pumping speed of 30m3/h.
Add-on network communication system and computer system highly integrated ChemAnalyst software for data acquisition and specified post-processing workstation(applicable to Win10)
Electronic control system  electronic measurement and circuit control system
Optional UPS (optional configuration)
Nitrogen generator (optional configuration)

Application

Biopharmaceutical: Synthetic drug detection (including CRO organic synthesis and biopeptide synthesis) and the detection of API (including synthetic API and traditional Chinese Medicine).
Detection for RoHS and ReachH : Super-fast screening of PAEs, PAHs, bisphenol A, PBBs and PBDEs.
Industrial Analysis: Production quality control of synthetic intermediate and finished products.
Environmental Monitoring: Monitoring and analysis of environmental pollutants.
Food Safety: Detection of food additives, food residues, pollutants, illegal additives, etc.

Advantage
1. The unique and innovative design of the ion source
The position of the ion source spray needle can be flexibly adjusted to be adaptable to the analysis of complex samples under different flow rates.The adoption of the patented heating technology and sheath gas fluid atomization technology
at the ion source atomization chamber has substantially improved the efficiency of atomization and desolvation , reduced the background noise, and increased the sensitivity of the instrument.The adoption of the ion optical off-axis design for the ion transmission at the ion source injection port contributes to a clean cone-hole for a much longer period of time and the
minimization of the interference caused by the pollution, improving the ion transmission efficiency and obtaining a better sensitivity.

2. The function of acquiring data from multiple channels has raised the analysis speed and work efficiency.
Full scan mode can be applied to the qualitative analysis of target compounds for one sample injection; SIM mode can be applied to the quantitative analysis of the target compounds.The SIM mode can be applied to the analysis of low concentration compounds or low response compounds, and the full scan mode can be applied to the analysis of unknown compounds with high concentration or high ionization efficiency.Free selection and combination of positive or negative ionization modes, SIM or full scan modes can support a scanning under different conditions of data acquisition for one sample injection, and the analysis of more complex samples, substantially improving the analysis speed
and working efficiency of the users.
3.A fast switching between positive and negative ionization modes can support a flexible test.
A higher response ionization mode can be selected and applied because of the capability of fast switching between positive and negative ionization modes, which is convenient to the optimization of the methods and conditions without affecting the integrity of the chromatography separation. It is suggested to obtain both the positive-ion and negative-ion mass spectrum for one sample injection of those compounds that can be ionized in both modes (positive-ion and negative-ion modes) for a more reliable result.

4 .Capability of obtaining abundant mass spectrum information, including molecular mass and multiple structural information.
The provision of in-source collision induced dissociation (CID) function has increased the structural fragmentation information, which is beneficial to the mass spectrum analysis of target compounds.

5.The ChemAnalyst software has powerful functions and its operation is simple because of the friendly user interface .
ChemAnalyst, as a powerful software of chemical workstation can simplify your data analysis work and make it become an automated processing workflow from mass spectrum calibration to methods setup, sample collection and data analysis. Advanced data-acquisition and data- processing modules support a separate use of them, which can make mass spectrum analysis much faster, easier and more efficient.

Factory Price Liquid Chromatography LC Ms Mass ChromatographyFactory Price Liquid Chromatography LC Ms Mass ChromatographyFactory Price Liquid Chromatography LC Ms Mass ChromatographyFactory Price Liquid Chromatography LC Ms Mass ChromatographyFactory Price Liquid Chromatography LC Ms Mass ChromatographyFactory Price Liquid Chromatography LC Ms Mass Chromatography
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2020

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company
Management System Certification
ISO 9001
Export Year
2014-03-18