Dw-Kft-40vc Drawell Automatic Electronic Titrator Karl Fischer Columetric Titrator Auto Volumetric Karl Fischer Titrator

Product Details
Customization: Available
After-sales Service: Online Technical Support
Warranty: 1 Year
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001
Export Year
2014-03-18
  • Dw-Kft-40vc Drawell Automatic Electronic Titrator Karl Fischer Columetric Titrator Auto Volumetric Karl Fischer Titrator
  • Dw-Kft-40vc Drawell Automatic Electronic Titrator Karl Fischer Columetric Titrator Auto Volumetric Karl Fischer Titrator
  • Dw-Kft-40vc Drawell Automatic Electronic Titrator Karl Fischer Columetric Titrator Auto Volumetric Karl Fischer Titrator
  • Dw-Kft-40vc Drawell Automatic Electronic Titrator Karl Fischer Columetric Titrator Auto Volumetric Karl Fischer Titrator
  • Dw-Kft-40vc Drawell Automatic Electronic Titrator Karl Fischer Columetric Titrator Auto Volumetric Karl Fischer Titrator
  • Dw-Kft-40vc Drawell Automatic Electronic Titrator Karl Fischer Columetric Titrator Auto Volumetric Karl Fischer Titrator
Find Similar Products
  • Overview
  • Product Feature
  • Technical Specification
  • Detailed Photos
  • Company Profile
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
DW-KFT-40VC
Customized
Customized
Structure
Desktop
Material
Stainless Steel
Certification
CE, ISO
Application
School, Hospital, Lab
Type
Titrator
Volumetric Range
(0.1mg~250)Mg
Volumetric Polarization Current Accuracy
1μa±0.2μa; 50μa±10μa
Volumetric Working Current
1μa±0.2μa; 50μa±10μa
Volumetric Repeatability
±0.5%
Coulometric Range
10μg~20mg
Coulometricpolarization Current Accuracy
1μa±0.2μa; 50μa±10μa
Coulometric Working Current
1, 1.86, 5, 10μg (H2O)/S
Coulometric Accuracy
± (5%+3) μg
Coulometric Repeatability
Rsd of 100μg Sample Measurement Result ≤3%
Transport Package
340*400*400mm
Specification
10kg
Trademark
Drawell
Origin
China
Production Capacity
50PCS/Month

Product Description

DW-KFT-40VC Drawell Automatic Electronic Titrator Karl Fischer Columetric Titrator Auto Volumetric Karl Fischer Titrator

Product Feature
  • GENERAL FEATURES
  • LCD display screen.
  • Titration methods, curves and results are displayed in detail.
  • Volumetric KF Titration and Coulometric KF Titration are supported.
  • Data analysis feature helps user review and compare results.
  • Data can be easily transferred to printer via RS-232 communication interface.
  • Reset feature automatically resumes all settings back to factory default options.

  • Coulometric Karl Fischer Titration
  • Generator cell with diaphragm.
  • Automatic/manual background drift correction ensures accurate results.
  • Selectable units including μg, mg, %, ppm, mg/L, μg/mL, etc.
  • Settable parameters, including measurement unit, polarization current, stirring rate, generator current, endpoint potential, stop criterion and etc.
  • Store up to 200 titration data sets (GLP-compliant).
  • Volumetric Karl Fischer Titration
  • Support KF Titration Mode and Titer Detection Mode.
  • Features of auto-filling, auto-purging and auto-mixing of the reagents ensure safe handling of Karl Fischer chemicals.
  • Automatic/manual background drift correction ensures accurate results.
  • Selectable units including mg, mg/L, %, ppm, etc.
  • Settable parameters, including measurement unit, polarization current, stirring rate, titration rate, stop volume, endpoint potential, stop criterion and etc.
  • Store up to 200 titration data sets (GLP-compliant).
Technical Specification
Model DW-KFT-40VC 
Volumetric Titration Range  (0.1mg~250)mg
Polarization Current Accuracy 1μA±0.2μA; 50μA±10μA
Repeatability ±0.5%
Coulometric Titration Range 10μg~20mg
Polarization Current Accuracy 1μA±0.2μA; 50μA±10μA
Working Current 1, 1.86, 5, 10μg (H2O)/S
Accuracy ± (5%+3) μg
Repeatability RSD of 100μg sample measurement result ≤3%
General Power Supply AC Adapter, 100-240 V AC input
Dimension (mm) & Weight (kg) 340×400×400; 10
 
Detailed Photos
Dw-Kft-40vc Drawell Automatic Electronic Titrator Karl Fischer Columetric Titrator Auto Volumetric Karl Fischer TitratorDw-Kft-40vc Drawell Automatic Electronic Titrator Karl Fischer Columetric Titrator Auto Volumetric Karl Fischer TitratorDw-Kft-40vc Drawell Automatic Electronic Titrator Karl Fischer Columetric Titrator Auto Volumetric Karl Fischer TitratorDw-Kft-40vc Drawell Automatic Electronic Titrator Karl Fischer Columetric Titrator Auto Volumetric Karl Fischer TitratorDw-Kft-40vc Drawell Automatic Electronic Titrator Karl Fischer Columetric Titrator Auto Volumetric Karl Fischer TitratorDw-Kft-40vc Drawell Automatic Electronic Titrator Karl Fischer Columetric Titrator Auto Volumetric Karl Fischer Titrator

 

Company Profile

 

Dw-Kft-40vc Drawell Automatic Electronic Titrator Karl Fischer Columetric Titrator Auto Volumetric Karl Fischer Titrator
Packaging & Shipping

Dw-Kft-40vc Drawell Automatic Electronic Titrator Karl Fischer Columetric Titrator Auto Volumetric Karl Fischer Titrator

FAQ

Dw-Kft-40vc Drawell Automatic Electronic Titrator Karl Fischer Columetric Titrator Auto Volumetric Karl Fischer Titrator

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier