Atomic Absorption Spectrophotometer Aas Laboratory Aas Atomic Absorption Spectrometer Price

Product Details
Customization: Available
After-sales Service: Online Technical Support
Application: Laboratory Apparatus
Still deciding? Get samples of US$ 6900/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001
Export Year
2014-03-18
  • Atomic Absorption Spectrophotometer Aas Laboratory Aas Atomic Absorption Spectrometer Price
  • Atomic Absorption Spectrophotometer Aas Laboratory Aas Atomic Absorption Spectrometer Price
  • Atomic Absorption Spectrophotometer Aas Laboratory Aas Atomic Absorption Spectrometer Price
  • Atomic Absorption Spectrophotometer Aas Laboratory Aas Atomic Absorption Spectrometer Price
  • Atomic Absorption Spectrophotometer Aas Laboratory Aas Atomic Absorption Spectrometer Price
  • Atomic Absorption Spectrophotometer Aas Laboratory Aas Atomic Absorption Spectrometer Price
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
Overview

Basic Info.

Model NO.
AAS320N
Warranty
1 Year
Detection Method
Spectrophotometer
Advantage
High Sensitive
Principle
New Spectrometer
Certification
CE
Customized
Non-Customized
Transport Package
Standard Package
Specification
1220x770x730mm (Main instrument) 800x400x900mm (
Trademark
Drawell
Origin
China
Production Capacity
1000 Pieces Per Year

Product Description

Atomic Absorption Spectrophotometer DW-AA320N

 

Product Description



Feature :
 

  1. Build-in computer data processing and LCD display: stable and reliable with the functions of integral holding, peak height and area, auto zero adjusting, lamp background correction, multi-linear and nonlinear curves fitting, various parameters and working curves displayed in screen and report printing, etc. It is equipped with interface for externally linking PC.
  2. Stability: Double-beam system can automatically compensate the light source drift and wavelength drift caused by the variation of temperature (with the function of the eliminating the affection of wavelength drift on the base line stability) and electronic circuit drift so as to reach a good basic line stability.
  3. Quickly: The cathode lamp needs not be pre-heated for long time and sample can be analyzed immediately. It is the preferable instrument chosen by users to conduct analysis of multiple kinds of elements and fast analysis of samples.
  4. High precision of measurement: Gas path system is equipped with precision pressure stabilizing and current stabilizing devices to reach stable flame and low noise. Specially designed fine light beam passes through the flame to ensure a high precision analytical test and low characteristic concentration
  5. High energy optical path: A total reflection system is adopted to eliminate color difference in full range. By means of chemical conversion, a round light spot of the light source becomes a long light spot, which enters into the slit. Therefore the light flux of double beam is enhanced.   
  6. Long-life and anti-corrosive atomization system: The burner is made of new type titanium alloys, anti-corrosive and fast thermal equilibrium. It meets the requirement of measurement sensitivity without water-cooling.
  7. Multi-functional analysis mode: for methods of flame absorption, flame emission, graphite furnace atomic absorption and hydride generation.
  8. Safe and reliable gas path system: Special devices of quick gas conversion and safety protection can be used to analyze air-acetylene flame as well as nitrous oxide-acetylene flame and extend the analytic elements to reach more than 60.
  9. Complete set of accessories: to be supplied with the instrument and ready for use after they are purchased.


Specifications
WL range (nm) 190-900
WL accuracy £ ±0.5nm
WL repeatability £ 0.3nm (single direction)
Spectrum bandwidth 0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm
Resolution <40%
Base line stability ±0.004Abs/30min
Characteristic concentration of copper £ 0.04mg/ml/1%
Detection limit of copper £0.008mg/ml
Background calibration ability Greater than 30 times
RS232 including
Printer optional
Power supply 220V 3A, 50Hz
G.W. 160Kg
65Kg
Package Dimensions 1220x770x730mm (Main instrument)
800x400x900mm  ( Accessories )
  1. Detailed Photos

     

    Atomic Absorption Spectrophotometer Aas Laboratory Aas Atomic Absorption Spectrometer PriceAtomic Absorption Spectrophotometer Aas Laboratory Aas Atomic Absorption Spectrometer PriceAtomic Absorption Spectrophotometer Aas Laboratory Aas Atomic Absorption Spectrometer Price

Atomic Absorption Spectrophotometer Aas Laboratory Aas Atomic Absorption Spectrometer PriceAtomic Absorption Spectrophotometer Aas Laboratory Aas Atomic Absorption Spectrometer PriceAtomic Absorption Spectrophotometer Aas Laboratory Aas Atomic Absorption Spectrometer Price

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier