Drawell Electric High Temperature DSC Calorimetry 600c Differential Scanning Calorimeter Price

Product Details
Customization: Available
After-sales Service: One Year
Warranty: Available
Still deciding? Get samples of US$ 3500/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001
Export Year
2014-03-18
  • Drawell Electric High Temperature DSC Calorimetry 600c Differential Scanning Calorimeter Price
  • Drawell Electric High Temperature DSC Calorimetry 600c Differential Scanning Calorimeter Price
  • Drawell Electric High Temperature DSC Calorimetry 600c Differential Scanning Calorimeter Price
  • Drawell Electric High Temperature DSC Calorimetry 600c Differential Scanning Calorimeter Price
  • Drawell Electric High Temperature DSC Calorimetry 600c Differential Scanning Calorimeter Price
  • Drawell Electric High Temperature DSC Calorimetry 600c Differential Scanning Calorimeter Price
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Certifications
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
BXT-DSC100
Structure
Desktop
Material
Contact
Certification
CE
Application
School, Hospital, Lab
Type
Calorimeter
Features
Used in The Research and Development
Model
Bxt-DSC100
DSC Range
0 ~ ±500MW
Temperature Range
Room Temperature~600ºC
Heating Rate
0.1~80ºC/Min
Temperature Resolution
0.01ºC
Transport Package
Contact
Specification
contact
Trademark
Drawell
Origin
China
Production Capacity
2000PCS/Month

Packaging & Delivery

Package Size
85.00cm * 50.00cm * 60.00cm
Package Gross Weight
30.000kg
Lead Time
30 days (1 - 1 Pieces)
To be negotiated ( > 1 Pieces)

Product Description

 
Product Description
BAXIT Differential scanning calorimeter BXT-DSC100

Features
  1. 1. The new fully enclosed metal furnace body design structure greatly improves
    the resolution and resolution and better baseline stability. To
    2. Using professional alloy sensor, it is more resistant to corrosion and oxidation,
    and the sensor has high sensitivity.
    3. Perfect two-way atmosphere control system, precise control of purge gas flow,
    automatic switching of software settings, and data directly recorded in the
    database.
    4. Using Cortex-M3 core ARM controller, the calculation processing speed is faster,
    and the temperature control is more accurate.
    5. Using USB two-way communication, the operation is more convenient and
    supports self-recovery connection function.
    6. Using 7-inch 24bit color full-color LCD touch screen, real-time display of the
    status and data of the instrument.
    7. The instrument is equipped with standard materials, and users can calibrate
    each temperature section by themselves to reduce the error of the instrument.                              
  2. 8. Intelligent software design, automatic drawing of the instrument in the whole
  3. process, the software can realize various data processing, such as the calculation of enthalpy, glass transition temperature, oxidation induction period, melting
    point and crystallization of substances, etc.
     

Product introduction
Differential scanning calorimeter (heat flow DSC) is a classic thermal analysis
method of thermal effects under controllable program temperature. It is used in the research and development, process optimization, quality control and failure
analysis of various materials and chemistry fields. It has been widely used in
various occasions. Using the DSC method, we can study the phase transition of   inorganic materials, the melting of polymer materials, the crystallization process,
the polymorphism of drugs, the solid/liquid ratio of foods such as oils and fats.


Specification Table:
DSC range 0 ~ ±500mW
Temperature range Room temperature~600ºC
Heating rate 0.1~80ºC/min
Temperature resolution 0.01ºC
Temperature repeatability ±0.1ºC
DSC noise 0.001mW
DSC resolution 0.001mW
DSC accuracy 0.001mW
DSC sensitivity 0.001mW

Temperature control method
heating,   constant   temperature   (full   progra
automatic control)
Curve scan heating scan
Atmosphere control automatic instrument switching
Gas flow rate 0-200mL/min
Gas pressure 0.2MPa
Display mode 24bit color 7-inch LCD touch screen display
Data interface standard USB interface


Parameter standard
Equipped with standard materials, with one-ke calibration     function,     users     can     calibra
temperature and enthalpy by themselves
   
Detailed Photos
Drawell Electric High Temperature DSC Calorimetry 600c Differential Scanning Calorimeter PriceDrawell Electric High Temperature DSC Calorimetry 600c Differential Scanning Calorimeter PriceDrawell Electric High Temperature DSC Calorimetry 600c Differential Scanning Calorimeter PriceDrawell Electric High Temperature DSC Calorimetry 600c Differential Scanning Calorimeter Price

 

Certifications

Drawell Electric High Temperature DSC Calorimetry 600c Differential Scanning Calorimeter PriceDrawell Electric High Temperature DSC Calorimetry 600c Differential Scanning Calorimeter Price

Packaging & Shipping
Drawell Electric High Temperature DSC Calorimetry 600c Differential Scanning Calorimeter PriceDrawell Electric High Temperature DSC Calorimetry 600c Differential Scanning Calorimeter Price

Drawell Electric High Temperature DSC Calorimetry 600c Differential Scanning Calorimeter Price

FAQ

 

Drawell Electric High Temperature DSC Calorimetry 600c Differential Scanning Calorimeter Price

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier