Dw-Gc1120 Laboratory Test Equipment Fid/Tcd/Fpd/Npd Gc Gas Chromatograph
Product Details
| Customization: | Available |
|---|---|
| After-sales Service: | Provided |
| Warranty: | 1 Year |
Diamond Member Since 2020
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Address
Room 2705, Building 12, No. 1 Shiyou Road, Yuzhong District, Chongqing, China
International Commercial Terms(Incoterms)
FOB, EXW, CFR, CIF, DAT, FAS, DDP, DAP, CIP, CPT, FCA
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram
Find Similar Products
Basic Info.
- Model NO.
- DW-GC1120
- Appliance
- The Analysis of Environmental Samples
- Detector
- Fid, Tcd, Ecd, Fpd, Npd, Pid
- Certification
- CE
- Chromatography Type
- Gas Chromatography
- Temperature Range
- 7℃ ~ 400℃
- Program Ramps
- 7
- Program Setting
- 0.1℃~40℃/Min
- Increment
- 0.1℃
- Total Time of Total Program
- up to 655 Minutes
- Certificate
- CE;ISO90001
- Transport Package
- Pure English Standard Export Wooden Box Packaging
- Specification
- 83*68*83; 85KGS
- Trademark
- DRAWELL
- Origin
- Shanghai, China
- Production Capacity
- 300
Product Description
DW-GC1120 Gas Chromatography
Hydrogen flame ionization detector (FID):
Minimum detectable quantity: M≤8×10-12g/s (C16)
Best test result: M≤3×10-12g/s (C16)
Noise: ≤5×10-14A
Drift: ≤6×10-13A/h
Linearity range: ≥106
Thermal conductivity detector(TCD):
Sensitivity:≥5000mV*mL/mg (C16)
Noise: ≤20µV
Drif: ≤30µV/h
Linearity rang: ≥104
High Sensitivity Thermal conductivity detector(HTCD):
Sensitivity: ≥10000mV*mL/mg (C16)
Electron capture detector(ECD):
Detectability: ≤1×10-13g/s (γ-666)
Linearity range: ≥103
Maximum using temperature: 350ºC
Flame photometric detector(FPD):
Detectability: ≤2×10-11g/s(P) (Parathion-methyl)
≤1×10-10g/s(S) (Parathion-methyl)
Nitrogen-phosphorus detector(NPD):
Detectability: ≤5×10-12g/s(N) (Azobenzene)
≤5×10-13g/s(P) (Malathion)
(On programmed)
Photoelectric ion detector(PID):
Detectability: ≤1ppb (Benzene)

Temperature Control :
Temperature Range:7ºC ~ 400ºC above room temperature, (increment 1ºC)
Temperature Control Object:Column Box, front and back detector, front and back sampler, assist,total six channels.
Program ramps : 7 ramps in total
Program setting:0.1ºC~40ºC/min(increment 0.1ºC)
Total time of total program : Up to 655 minutes, (increment 0.1ºC)
Hydrogen flame ionization detector (FID):
Minimum detectable quantity: M≤8×10-12g/s (C16)
Best test result: M≤3×10-12g/s (C16)
Noise: ≤5×10-14A
Drift: ≤6×10-13A/h
Linearity range: ≥106
Thermal conductivity detector(TCD):
Sensitivity:≥5000mV*mL/mg (C16)
Noise: ≤20µV
Drif: ≤30µV/h
Linearity rang: ≥104
High Sensitivity Thermal conductivity detector(HTCD):
Sensitivity: ≥10000mV*mL/mg (C16)
Electron capture detector(ECD):
Detectability: ≤1×10-13g/s (γ-666)
Linearity range: ≥103
Maximum using temperature: 350ºC
Flame photometric detector(FPD):
Detectability: ≤2×10-11g/s(P) (Parathion-methyl)
≤1×10-10g/s(S) (Parathion-methyl)
Nitrogen-phosphorus detector(NPD):
Detectability: ≤5×10-12g/s(N) (Azobenzene)
≤5×10-13g/s(P) (Malathion)
(On programmed)
Photoelectric ion detector(PID):
Detectability: ≤1ppb (Benzene)
| Optional Parts | Main function |
| GC1120-TCD | Thermal conductivity detector |
| GC1120-ECD | Electron capture detector |
| GC1120-FPD | Flame photometer detector |
| GC1120-NPD | Nitrogen phosphorous detector |
| Chromatographic work station | External interface box + work station (not include PC) |
| Simulation software | Imitation find chromatographic condition, emulation teaching, train and knowledge base. |




Send your message to this supplier
People who viewed this also viewed
Product Groups
More
Find Similar Products By Category
- Supplier Homepage
- Products
- Chromatograph
- GC (Gas Chromatograph)
- Dw-Gc1120 Laboratory Test Equipment Fid/Tcd/Fpd/Npd Gc Gas Chromatograph
Related Categories
Hot Searches
More