Customization: | Available |
---|---|
Classification: | Biochemical Apparatus |
Type: | Biochemistry Analyzer |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
System Functions- Fully automatically, discrete, random STAT function - Online test items: at most 40 testing items- Throughput: 400 tests/hour- Analysis Method: end-point, kinetic, two-point, double-reagents, double-wavelength, multi-standard etc, open to various reagents- Data Processing: memory up to 2 million patients' data
Sample/Reagents Handling- Sample Position: 93 pcs (Include standard, QC, STAT positions)- Sample volume: 2-50µl, 0.1µl step- Sample Probe Cleaning: automatic internal & external washing- Sample Dilution: automatic/Manual pre-dilution, with dilution ratio up to 1:100- Reagent Position: 80 pcs (With refrigerated function, 2ºC-8ºC ) - Reagent Volume: 10-500µl, 1µl step- Reagent Probe: automatic liquid level detect, with collision protection function- Reagent Probe Cleaning: automatic internal & external washing
Reaction System- Reaction Cuvette: 90 pcs made of special material- Optical Length of Cuvette: 6mm- Reaction Volume: 200~500µl- Reaction Time: 8-14 minutes- Reaction Temperature: 37ºC±0.1ºC- Mixing System: two independent mixing probe
Optical System- Light Source: halogen-tungsten lamp- Wavelength: 300-700nm, 9 wavelengths, precision ±2nm- Spectrophotometry: rear spectrophotometry- Test Range: 0-4.0 Abs- Resolution: 0.001Abs
Bar-code Reader (Optional)- Bar-code reader used for sample/reagent programming
ISE Module (Optional)- Optional 1: K, Na, Cl, Ca, PH (5 items)- Throughput: 300 tests/hour- Optional 2: K, Na, Cl (3 items)- Throughput: 180 tests/hour
QC- Various QC management function and random QC insert Control and Calibration- Calibration: linear/nonlinear multi-points calibration- Re-test: retest the sample automatically when the result is out of the linearity range or the sample is not sufficient- Automatic sample dilute function
Cleaning System- 8-step automatic washing, automatic cuvette dry function Water Consumption: 8L/hour
Working Condition- Power Supply: ~100-240V, 50/60Hz, 1KVA- Temperature: 10-35ºC- Humidity: ≤90%, no dew
Operation SystemWindows XP or Windows 2000
Input and Output- Input: RS-232 interface / keyboard / computer- Output: multi-format printout
Dimension and Weight- Upper cabinet: 950×710×1180mm Net Weight: 136kgs
Packing Information- 890×1135×1400mm; G.W.: 215kgs (With plywood case)
R1 Reagent Position- 40 pcs R1 reagent positions- Non-stop reagents refrigerating- Auto detect of reagent volume
R2 Reagent/Sample position - 40 pcs R2 reagent positions- 93 sample positions, suitable for- primary tube abd serum cup- Non-stop reagents refrigerating- Auto detect of reagent volume
Sample/Reagent Probe - Probe telflon coating technology- Automatic liquid level detect- Collision protection function- Independent mixing probe- Probe internal/external washing
Reaction Cuvettes- 90 pcs reusable cuvettes- Automatic blank testing for cuvette- Dismountable, easy to replace Cuvette- Advanced thermostat to ensure accurate test result
8-step auto cleaning System- Automatic 8-step washing - Automatic cuvette dry function- Hi-tech washing station to ensure accurate test results- With low water consumption: 8L/H
Mixing Probe- Two independant mxing probes- High precision mixing station- Collision protection function- Probe internal/external washing- Probe telflon coating technology
- Automatic washing cuvette when start up & shut down the instrument- Test order setting program is available to avoid carry-over- Automatic detect reagent volume during every startup of the instrument- Show reagent plate temperature during every startup of the instrument
Automatic Cuvette blank testing - Automatic wash selected cuvettes - Real-time online monitoring running status of cuvette -
- Real-time online monitoring running status of sample tray, reagent tray cuvette- Real-time online monitoring reagents residual volume- Real-time online monitoring waste volume
Automatic dilute and re-test when absorbance range is overrange -Automatic dilute and re-test when linear limit is overrange -Three modes (no dilute, autodilute and handwork dilute) are available -Freely set the autodilute ratio and dilute water position -
- Freely set the autodilute ratio when re-testing- "No dilute" re-testing mode is available