Secured Trading Service

Gc1120 Drawell Gc Chromatography Gas Analyzer Gas Chromatograph

Chongqing Drawell Instrument Co., Ltd.
  • Audited Supplier
  • 7 yrs

Contact Supplier

Product Highlights

  • Multi-Channel Temperature Control: Controls column box, detectors, and samplers with six independent temperature channels.
  • Flexible Sample Introduction: Up to three injectors can be installed simultaneously with independent temperature control.
  • Multi-Detector Capability: Supports up to three detectors (FID, TCD, ECD, etc.) operating simultaneously in series or parallel.
  • Precision Pneumatic Control: Features constant pressure and flow valves with digital displays for high reproducibility.
  • Comprehensive Certification: Certified with CE and ISO standards ensuring safety and quality compliance.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of Gc1120 Drawell Gc Chromatography Gas Analyzer Gas Chromatograph

Gc1120 Drawell Gc Chromatography Gas Analyzer Gas Chromatograph
Gc1120 Drawell Gc Chromatography Gas Analyzer Gas Chromatograph pictures & photos
Gc1120 Drawell Gc Chromatography Gas Analyzer Gas Chromatograph
Gc1120 Drawell Gc Chromatography Gas Analyzer Gas Chromatograph pictures & photos
Gc1120 Drawell Gc Chromatography Gas Analyzer Gas Chromatograph
Gc1120 Drawell Gc Chromatography Gas Analyzer Gas Chromatograph pictures & photos
Gc1120 Drawell Gc Chromatography Gas Analyzer Gas Chromatograph
Gc1120 Drawell Gc Chromatography Gas Analyzer Gas Chromatograph pictures & photos
Gc1120 Drawell Gc Chromatography Gas Analyzer Gas Chromatograph
Gc1120 Drawell Gc Chromatography Gas Analyzer Gas Chromatograph pictures & photos
Gc1120 Drawell Gc Chromatography Gas Analyzer Gas Chromatograph
Gc1120 Drawell Gc Chromatography Gas Analyzer Gas Chromatograph pictures & photos
Gc1120 Drawell Gc Chromatography Gas Analyzer Gas Chromatograph
  • Gc1120 Drawell Gc Chromatography Gas Analyzer Gas Chromatograph
  • Gc1120 Drawell Gc Chromatography Gas Analyzer Gas Chromatograph
    Gc1120 Drawell Gc Chromatography Gas Analyzer Gas Chromatograph
  • Gc1120 Drawell Gc Chromatography Gas Analyzer Gas Chromatograph
    Gc1120 Drawell Gc Chromatography Gas Analyzer Gas Chromatograph
  • Gc1120 Drawell Gc Chromatography Gas Analyzer Gas Chromatograph
    Gc1120 Drawell Gc Chromatography Gas Analyzer Gas Chromatograph
  • Gc1120 Drawell Gc Chromatography Gas Analyzer Gas Chromatograph
    Gc1120 Drawell Gc Chromatography Gas Analyzer Gas Chromatograph
  • Gc1120 Drawell Gc Chromatography Gas Analyzer Gas Chromatograph
    Gc1120 Drawell Gc Chromatography Gas Analyzer Gas Chromatograph
  • Gc1120 Drawell Gc Chromatography Gas Analyzer Gas Chromatograph
    Gc1120 Drawell Gc Chromatography Gas Analyzer Gas Chromatograph

Find Similar Products

Product Description

GC1120 Drawell GC Chromatography Gas Analyzer Gas Chromatograph
Gc1120 Drawell Gc Chromatography Gas Analyzer Gas Chromatograph
Product Feature

Temperature Control :
Temperature Range:7ºC ~ 400ºC above room temperature, (increment 1ºC)
Temperature Control Object:Column Box, front and back detector, front and back sampler, assist,total six channels.
Program ramps : 7 ramps in total
Program setting:0.1ºC~40ºC/min(increment 0.1ºC)
Total time of total program : Up to 655 minutes, (increment 0.1ºC)

Hydrogen flame ionization detector (FID):
Minimum detectable quantity: M≤8×10-12g/s (C16)
Best test result: M≤3×10-12g/s (C16)
Noise: ≤5×10-14A
Drift: ≤6×10-13A/h
Linearity range: ≥106

Thermal conductivity detector(TCD):
Sensitivity:≥5000mV.mL/mg (C16)
Noise: ≤20µV
Drif: ≤30µV/h
Linearity rang: ≥104

High Sensitivity Thermal conductivity detector(HTCD):
Sensitivity: ≥10000mV.mL/mg (C16)

Electron capture detector(ECD):
Detectability: ≤1×10-13g/s  (γ-666)
Linearity range: ≥103
Maximum using temperature:  350ºC

Flame photometric detector(FPD):
Detectability: ≤2×10-11g/s(P)  (Parathion-methyl)
                       ≤1×10-10g/s(S)  (Parathion-methyl)

Nitrogen-phosphorus detector(NPD):
Detectability: ≤5×10-12g/s(N)  (Azobenzene)
                     ≤5×10-13g/s(P)  (Malathion)  (On programmed)

Photoelectric ion detector(PID):
Detectability: ≤1ppb             (Benzene)

Technical Specification
Flexible Sample Introduction System
Up to three injectors may be installed and operated simultaneously with independent temperature control. Wide range of injectors is available to be chosen from for various applications. It is very convenient for installation and disassembly of sample injectors.
Sample Injector with Mono Packed Column/Double Packed Columns:
Several alternative sample introduction methods, including on-column sample introduction and six-way valve injection;
Adapter for injection to capillary column (0.53 mm i.d.).
Sample injector for capillary column
Special sample injector with septum purge and back-pressure valve splitting;
Special programmable split/splitless injector with solenoid valve, septum purge, back-pressure valve splitting, and standalone carrier gas and make-up gas flow;
Modified dual-packed-column sample injector for injection to capillary column by employing some connectors and back-pressure valve splitting.

Advanced Pneumatics
Carrier gas control with constant pressure valve and constant flow valve;
Air and hydrogen control with constant pressure valve and needle valve;
Flow easily adjustable through constant flow valve and needle valve with digital display;
High precision, reproducibility and reliability.

Sensitive and reliable detector
Up to three detectors (FID, TCD, ECD, etc) may be installed and operated simultaneously. Simultaneous multi-detection with detectors in series or in parallel meets the various analysis requirements.
The new FID provides higher sensitivity than ever before. It is very convenient to disassemble and clean the jet and collector. Precisely fixed emitter configuration ensures conformity of product performance;
Excellent TCD detector with high-resistance tungsten-rhenium filaments provides high sensitivity. A sensitivity of 10000 mV·mL/mg is achieved with optional amplifier circuit board. Special configuration of air heat insulation enhances the stability of TCD detector
Constant-current, pulse-modulated ECD detector sets sensitivity and current by computer.

 
Detailed Photos

Gc1120 Drawell Gc Chromatography Gas Analyzer Gas ChromatographGc1120 Drawell Gc Chromatography Gas Analyzer Gas ChromatographGc1120 Drawell Gc Chromatography Gas Analyzer Gas ChromatographGc1120 Drawell Gc Chromatography Gas Analyzer Gas ChromatographGc1120 Drawell Gc Chromatography Gas Analyzer Gas Chromatograph

Recommend Products

Gc1120 Drawell Gc Chromatography Gas Analyzer Gas Chromatograph

Company Profile

Gc1120 Drawell Gc Chromatography Gas Analyzer Gas Chromatograph

Why choose us
Gc1120 Drawell Gc Chromatography Gas Analyzer Gas Chromatograph
Our Service
Gc1120 Drawell Gc Chromatography Gas Analyzer Gas ChromatographGc1120 Drawell Gc Chromatography Gas Analyzer Gas Chromatograph
FAQ
Gc1120 Drawell Gc Chromatography Gas Analyzer Gas Chromatograph

About the Supplier

This supplier has been audited by SGS. Verify the report on the official SGS website with ID "QIP-ASR2391291". Items marked "verified" are certified.

Watch Video
Watch Video
Chongqing Drawell Instrument Co., Ltd.
Chongqing Drawell Instrument Co., Ltd.
Chongqing Drawell Instrument Co., Ltd.
Chongqing Drawell Instrument Co., Ltd.
Chongqing Drawell Instrument Co., Ltd.
Chongqing Drawell Instrument Co., Ltd.
Chongqing Drawell Instrument Co., Ltd.
Chongqing Drawell Instrument Co., Ltd.

About Our Factory & Business Background

Address
Room 2204, Building 11, No. 1 Shiyou Road, Yuzhong District, Chongqing, China
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram
International Commercial Terms(Incoterms)
FOB, EXW, CFR, CIF, DAT, FAS, DDP, DAP, CIP, CPT, FCA
Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays
Nearest Port
Shanghai, Guangzhou, Shenzhen and etc.

Our Production Capability & Technical Expertise

Main Products
Spectrophotometer/ Spectrometer, Autoclave, PCR, Chromatograph, Freezer, Incubator and Oven, Centrifuge, Microscope, Rotary Evaporator, Balance

Our Industry Experience & Global Business Record

Export Year
2014-03-18
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

How many temperature control channels are available?
There are six independent channels for the column box, front and back detectors, and front and back samplers.
Can multiple detectors be used at the same time?
Yes, up to three detectors such as FID, TCD, and ECD can be installed and operated simultaneously.
What is the warranty period for this instrument?
The product comes with a 1-year warranty.
What after-sales support is provided?
Online technical support is available for all customers.
What certifications does the gas chromatograph have?
The device is certified with CE and ISO standards.
What are the lead times for delivery?
Peak season lead time is one month, while off-season lead time is within 15 workdays.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now