• Automatic Chemistry Analyzer
  • Automatic Chemistry Analyzer
  • Automatic Chemistry Analyzer
  • Automatic Chemistry Analyzer
  • Automatic Chemistry Analyzer
  • Automatic Chemistry Analyzer

Automatic Chemistry Analyzer

Classification: Biochemical Apparatus
Type: Biochemistry Analyzer
Certification: CE
Group: All of Above
Transport Package: Wooden Carton
Trademark: DRAWELL
Customization:
Diamond Member Since 2020

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company
  • Overview
  • Product Description
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
DW-TC6030
Origin
China
HS Code
9027509090

Product Description

Product Description

                               DW-TC6030 Automatic Chemistry Analyzer
System Functions
- Fully automatically, discrete, random STAT function
- Online test items: at most 40 testing items
- Throughput: 260 tests/hour
- Analysis Method: end-point, kinetic, two-point, double
  -reagents,double-wavelength, multi-standard etc, open
   to various reagents
- Data Processing: memory up to 200,000 patients' data
 
Sample/Reagents Handling
- Sample Position: 40 pcs (Include standard,QC,STAT positions)
- Sample volume: 2-50µl, 0.1µl step
- Sample Probe Cleaning: automatic internal & external washing
- Sample Dilution: automatic/Manual pre-dilution, with
  dilution ratio up to 1:100
- Reagent Position: 40 pcs (With refrigerated function, 2ºC-8ºC)
- Reagent Volume: 10-500µl, 1µl step
- Reagent Probe: automatic liquid level detect, with collision
  protection function
- Reagent Probe Cleaning: automatic internal & external washing
 
 Reaction System
- Reaction Cuvette: 90 pcs made of special material
- Optical Length of Cuvette: 6mm
- Reaction Volume: 200~500µl
- Reaction Time: 8-10 minutes
- Reaction Temperature: 37ºC±0.1ºC
- Mixing System: independent mixing probe
 
Optical System
- Light Source: halogen-tungsten lamp
- Wavelength: 300-700nm, 9 wavelengths, precision ±2nm
- Absorbance Range: 0~4.0Abs
- Resolution: 0.001Abs
- Spectrophotometry: rear spectrophotometry
 
 QC
- Various QC managements, insert QC randomly; save,
  display & print QC chart; define different QC in advance
 
 Calibration
- Calibration: linear/nonlinear multi-points calibration
- Re-test: retest the sample automatically when the result
  is out of the linearity range or the sample is not sufficient
 
Cleaning System
- 8-step automatic washing, automatic cuvette dry function
- Water Consumption: 4L/hour
 
Working Condition
- Power Supply: ~100-240V, 50/60Hz, 1KVA
- Temperature: 10ºC-35ºC
- Humidity: ≤90%, no dew
 
Operation System
Windows XP or Windows 2000
 
Input and Output
- Input: RS-232 interface / keyboard / computer
- Output: multi-format printout
 
Dimension and Weight
- Upper cabinet: 700×650×530mm
  Net Weight: 62kgs
- Bottom cabinet: 700×705×620mm
  Net Weight: 47kgs
 
Packing Information
- Adopts plywood case
- Upper Cabinet: 830×880×732mm    G.W.: 95kgs
- Bottom Cabinet: 800×880×855mm   G.W.: 74kgs
 
Sample/Reagent Position
- 40 pcs sample position
- 40 pcs reagent position
- Reagents refrigerated function
- Primary tube and blood serum
  cup can be used
 
Sample/Reagent/Mixing Probe              
- Probe telflon coating technology
- Automatic liquid level detect
- Collision protection function
- Independent mixing probe
- Probe internal/external washing
- Clot detection function
 
Reaction Cuvettes
- 90 pcs reusable cuvettes
- Automatic blank testing for cuvette
- Colorimetry system in the pattern of
   light splitting behind cuvette
- Dismountable, easily replace cuvette
 
8-step auto cleaning System
- Automatic 8-step washing
- Automatic cuvette dry function
- Hi-tech washing station to ensure
  accurate test results
- With low water consumption: 4L/H
 
- Automatic washing cuvette when start up & shut down the instrument
- Test order setting program is available to avoid carry-over
- Automatic detect reagent volume during every startup of the instrument
- Show reagent plate temperature during every startup of the instrument
 
Automatic Cuvette blank testing -
Automatic wash selected cuvettes -
Real-time online monitoring running status of cuvette -
 
- Real-time online monitoring running status of sample tray, reagent
   tray cuvette
- Real-time online monitoring reagents residual volume
- Real-time online monitoring waste volume
 
Automatic dilute and re-test when absorbance range is overrange -
Automatic dilute and re-test when linear limit is overrange -
Three modes (no dilute, autodilute and handwork dilute) are available -
Freely set the autodilute ratio and dilute water position -
 
- Freely set the autodilute ratio when re-testing
- "No dilute" re-testing mode is availablet
 

Company Profile

Automatic Chemistry AnalyzerAutomatic Chemistry Analyzer

FAQ

 

Automatic Chemistry Analyzer

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Product Groups

Diamond Member Since 2020

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company
Management System Certification
ISO 9001
Export Year
2014-03-18