Dw-Gc1290 Gas Chromatograph LCD Touch Screen Gas Chromatography High Precision Gas Analyzer Chromatography Analysis Instrument Gas Chromatograph
|
Still deciding? Get samples of $ !
Request Sample
|
Product Details
| Customization: | Available |
|---|---|
| After-sales Service: | Online Service |
| Warranty: | 1year |
Diamond Member Since 2020
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Address
Room 2705, Building 12, No. 1 Shiyou Road, Yuzhong District, Chongqing, China
International Commercial Terms(Incoterms)
FOB, EXW, CFR, CIF, DAT, FAS, DDP, DAP, CIP, CPT, FCA
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram
Find Similar Products
Basic Info.
- Model NO.
- DW-GC1290
- Appliance
- The Analysis of Environmental Samples
- Ray Type
- /
- Gaspath System
- /
- Detector
- /
- Energy Resolution
- /
- Certification
- CE, ISO
- Spectrometer Detector
- UV
- Stationary Phase
- Liquid Solvent
- Mobile Phase
- Liquid
- Chromatography Type
- Gas Chromatography
- Chromatographic Column Type
- Capilary Column
- Chromatographic Column Length
- 10~30cm
- Chromatographic Column Diameter
- 1~2mm
- Temperature Range
- Ambient Temperature +7℃ ~ 420℃
- Temperature Accuracy
- ± 0.02℃
- Program Ramps
- 20 Ramps in Total (99 Ramps Available with Control
- Cooling Time
- 350℃-100&Ordm
- Programmed Temperature Setting
- 0.1℃~80℃/Min (in 1℃ Increment)
- Detection Limit
- ≤8×10-12g/S (N-Hexadecane)
- Drift
- ≤1.5×10-13A/H
- Noise
- ≤3×10-14A
- Linearity Range
- ≥106
- Transport Package
- Wooden Box
- Specification
- 83*68*83; 85KGS
- Trademark
- Drawell
- Origin
- Chongqing, China
- HS Code
- 9027201200
- Production Capacity
- 100pieces/Month
Product Description
Gas Chromatography
| Model# | DW-GC1290 | ||
| Description | EPC(electronic pneumatic control) 7 inch touch screen display |
||
| Sample Introduction System | sample injector and evaporation chamber | ||
| Column Oven | Temperature range | Ambient temperature +7ºC ~ 420ºC (in 1ºC increment) | |
| Temperature accuracy | ± 0.02ºC | ||
| Cooling time | 350ºC~100ºC≤3min, 400ºC~50ºC in 8-10 min at 25ºC ambient | ||
| Programmed temperature setting | 0.1ºC~80ºC/min (in 1ºC increment) | ||
| Program ramps | 20 ramps in total (99 ramps available with control workstation) | ||
| Size (L*W*H) | 284*280*241mm(inside) | 340*345*281mm(outside) | |
| Flame Ionization Detector (FID) |
Detection limit | ≤8×10-12g/s (n-hexadecane) | |
| Drift | ≤1.5×10-13A/h | ||
| Noise | ≤3×10-14A | ||
| Linearity range | ≥106 | ||
| Flame Photometric Detector (FPD) |
Detection limit | ≤8×10‐13g/s(P) ; ≤8×10‐11g/s(S) | |
| Drift | ≤2×10‐11A/30min | ||
| Baseline noise | ≤5×10‐12A | ||
| Nitrogen-Phosphorus Detector (NPD) |
Detection limit | ≤5×10-12g/s(N) (Azobenzene) ≤5×10-13g/s(P) (Malathion) |
|
| Features: | |||
| ★Control system: designed for monitoring and controlling the instrument via the computer. ★Column Compartment/oven with superior thermal performance, multistage (20 ramps) programmed temperature control function. (supported by "control system") ★Advanced built-in data acquisition system , supporting real time instrument status monitoring, detection signal acquisition and PC control ★Column oven supports quick heat-up and rapid cool-down with automated back-door opening. ★Flexible sample introduction system: 2 sample injectors could be installed and operated simultaneously with independent temperature control. ★High sensibility and stability detector. ★2 independent and analog signals output. ★M6 software, compatible with GLP/FDA-21 CFR Part11 requirements and regulations. (electronic records and signatures) |
|||
| Electronic pneumatics control system | |||
| Flow rate: 200ml/min (N2), 1000ml/min (He) Flow rate accuracy: ±5% Flow rate repeatability: ±0.35% Split ratio: 0-5000(He), 0-1000(N2) Inlet temperature: 0-420ºC |
|||
| Gas chromatography and accessories: | |||
Carrier Gas System + Sample Introduction System + Separation System + Temperature Control System + Detector Carrier Gas System: air source/ purification and desiccation device/ flow rate control device Sample Introduction System: sample injector Separation System: chromatographic column(packed column and capillary column) Temperature Control System (Column Oven): constant temperature and programmed temperature Detector: FID/ FPD/ NPD |
|||
| Advanced Microcomputer Control System | |||
| ★Superior performance with advanced, microcomputer-based temperature control system ★High temperature accuracy (optimum ± 0.02ºC), high reliability, and anti-interference ★Self-diagnosis/ self-protection function (overheat protection, power-off protection, etc.) ★Intuitive display of timing program, detector status, measurement range, current setting, etc |
|||








Send your message to this supplier
People who viewed this also viewed
Product Groups
More
Find Similar Products By Category
- Supplier Homepage
- Products
- Chromatograph
- GC (Gas Chromatograph)
- Dw-Gc1290 Gas Chromatograph LCD Touch Screen Gas Chromatography High Precision Gas Analyzer Chromatography Analysis Instrument Gas Chromatograph
Related Categories
Hot Searches
More