Lab Analysis Instrument High Frequency Infrared Carbon Sulfur Analyzer for Metal Mineral Coal

Product Details
Customization: Available
After-sales Service: Online Technical Support
Application: Laboratory Apparatus
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001
Export Year
2014-03-18
  • Lab Analysis Instrument High Frequency Infrared Carbon Sulfur Analyzer for Metal Mineral Coal
  • Lab Analysis Instrument High Frequency Infrared Carbon Sulfur Analyzer for Metal Mineral Coal
  • Lab Analysis Instrument High Frequency Infrared Carbon Sulfur Analyzer for Metal Mineral Coal
  • Lab Analysis Instrument High Frequency Infrared Carbon Sulfur Analyzer for Metal Mineral Coal
  • Lab Analysis Instrument High Frequency Infrared Carbon Sulfur Analyzer for Metal Mineral Coal
  • Lab Analysis Instrument High Frequency Infrared Carbon Sulfur Analyzer for Metal Mineral Coal
Find Similar Products
  • Overview
  • Product Feature
  • Technical Specification
  • Detailed Photos
  • Company Profile
  • Why choose us
  • Our Service
  • FAQ
Overview

Basic Info.

Model NO.
DW-CS-8820
Warranty
1 Year
Detection Method
Spectrophotometer
Advantage
High Sensitive
Principle
Classic Spectrometer
Wavelengths
Infrared Spectrometer
Dispersive Element
Interferometer Spectrometer
Light Number
Monochromator
Certification
CE
Customized
Customized
C Measuring Range
0.0001%-10.0000%
S Measuring Range
0.0001%-3.5000%
Analysis of Error
with GB / T20123-2006/ ISO15350: 2000 Standard
Analysis Time
25-60 Seconds Can Be Set ( Usually 35 Seconds)
High Frequency Furnace
Power 2.7kVA
Oscillation Frequency
20MHz
Electronic Balance
Accuracy of Reading: 0.0001g
Indoor Temperature
10-30degree
Transport Package
Standard English Package
Specification
75cm*57cm*96cm; 105cm*66cm*90cm
Trademark
Drawell
Origin
China
Production Capacity
50pieces/Month

Product Description

DW-CS-8820 Lab Testing Analyzer Type High-frequency Infrared Carbon Sulfur Analyzer
Product Feature

Main features

(1). Adopting the double CPU design, electronic circuit integration degree is highly, steady and reliable, which can settle the high-frequency interference thoroughly.
(2). The special new platinum infrared light source, Gold plated carbon sulfur analysis pool and high precision pyroelectric infrared detector to make the apparatus' measurement more accurate.
(3). Adopting the high power and quick frequency circuit design, which using 6KVA high frequency power tube(actual use of power is about 2.5KVA, it can turn on to work itself), to reduce the high frequency combustion system load and to increase the using time.
(4). Furnace head automatic cleaning device, patent technology supply system and -0.4mm amd hole metal filter to make the dust and gas seperated, reducing the dust on the result of analysis.
(5). Specialized analysis software of many different language owns following functions: curve/data storage, blank deduction, parameter determination, channel choosing, data statistics, results correction, breakpoint correction, curve comparison, system diagnosis, automatic/manual printing analysis results etc.

 
Technical Specification
Measuring range C: 0.0001%-10.0000% (can extend to 99.9999%)  
S: 0.0001%-3.5000% (can extend to 99.9999%)
Analysis of error With GB / T20123-2006/ ISO15350: 2000 standard
Analysis time 25-60 seconds can be set ( usually 35 seconds)
High frequency furnace power ≥2.7KVA Oscillation frequency:20MHz
Electronic balance weight the sample in variable amount  Accuracy of reading:0.0001g
Working environment indoor temperature:10-30ºC,relative humidity:<90%
Power supply voltage:AC220V±5%,frequency:50Hz±2%
Oxygen Purity: ≥99.5%,  input pressure : 0.18MPa + 5%
 
Detailed Photos

Lab Analysis Instrument High Frequency Infrared Carbon Sulfur Analyzer for Metal Mineral CoalLab Analysis Instrument High Frequency Infrared Carbon Sulfur Analyzer for Metal Mineral CoalLab Analysis Instrument High Frequency Infrared Carbon Sulfur Analyzer for Metal Mineral Coal

Company Profile

Lab Analysis Instrument High Frequency Infrared Carbon Sulfur Analyzer for Metal Mineral Coal

Why choose us
Lab Analysis Instrument High Frequency Infrared Carbon Sulfur Analyzer for Metal Mineral Coal
Our Service
Lab Analysis Instrument High Frequency Infrared Carbon Sulfur Analyzer for Metal Mineral CoalLab Analysis Instrument High Frequency Infrared Carbon Sulfur Analyzer for Metal Mineral Coal
FAQ
Lab Analysis Instrument High Frequency Infrared Carbon Sulfur Analyzer for Metal Mineral Coal

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier