Drawell Dw-Ty-9000 Metal Quantitative Full Spectrum Analysis Instrument Spark Direct Reading Spectrometers

Chongqing Drawell Instrument Co., Ltd.
  • Audited Supplier
  • 7 yrs

Contact Supplier

Product Highlights

  • Full Spectrum Analysis: Covers 130-800nm wavelength range for comprehensive metal detection.
  • High Resolution Detection: Utilizes high-performance CCD array and vacuum optics for precise results.
  • Fast Testing Time: Generally completes analysis in about 25 seconds depending on sample type.
  • Customized Service: Offers customized detection for various substrates including Fe, Al, Cu, Ni, Ti, etc.
  • Digital Excitation Technology: Features new digital adjustable light source with HEPS technology up to 1000Hz.
  • ISO9001 & CE Certified: Meets international standards for design, manufacturing, and safety.
  • 1 Year Warranty: Comprehensive warranty coverage for mechanical defects and parts.
  • Online Technical Support: Provides remote assistance for installation, operation, and troubleshooting.

Product Images of Drawell Dw-Ty-9000 Metal Quantitative Full Spectrum Analysis Instrument Spark Direct Reading Spectrometers

Drawell Dw-Ty-9000 Metal Quantitative Full Spectrum Analysis Instrument Spark Direct Reading Spectrometers pictures & photos
Drawell Dw-Ty-9000 Metal Quantitative Full Spectrum Analysis Instrument Spark Direct Reading Spectrometers
Drawell Dw-Ty-9000 Metal Quantitative Full Spectrum Analysis Instrument Spark Direct Reading Spectrometers pictures & photos
Drawell Dw-Ty-9000 Metal Quantitative Full Spectrum Analysis Instrument Spark Direct Reading Spectrometers
Drawell Dw-Ty-9000 Metal Quantitative Full Spectrum Analysis Instrument Spark Direct Reading Spectrometers pictures & photos
Drawell Dw-Ty-9000 Metal Quantitative Full Spectrum Analysis Instrument Spark Direct Reading Spectrometers
Drawell Dw-Ty-9000 Metal Quantitative Full Spectrum Analysis Instrument Spark Direct Reading Spectrometers pictures & photos
Drawell Dw-Ty-9000 Metal Quantitative Full Spectrum Analysis Instrument Spark Direct Reading Spectrometers
Drawell Dw-Ty-9000 Metal Quantitative Full Spectrum Analysis Instrument Spark Direct Reading Spectrometers pictures & photos
Drawell Dw-Ty-9000 Metal Quantitative Full Spectrum Analysis Instrument Spark Direct Reading Spectrometers
Drawell Dw-Ty-9000 Metal Quantitative Full Spectrum Analysis Instrument Spark Direct Reading Spectrometers pictures & photos
Drawell Dw-Ty-9000 Metal Quantitative Full Spectrum Analysis Instrument Spark Direct Reading Spectrometers
  • Drawell Dw-Ty-9000 Metal Quantitative Full Spectrum Analysis Instrument Spark Direct Reading Spectrometers
    Drawell Dw-Ty-9000 Metal Quantitative Full Spectrum Analysis Instrument Spark Direct Reading Spectrometers
  • Drawell Dw-Ty-9000 Metal Quantitative Full Spectrum Analysis Instrument Spark Direct Reading Spectrometers
    Drawell Dw-Ty-9000 Metal Quantitative Full Spectrum Analysis Instrument Spark Direct Reading Spectrometers
  • Drawell Dw-Ty-9000 Metal Quantitative Full Spectrum Analysis Instrument Spark Direct Reading Spectrometers
    Drawell Dw-Ty-9000 Metal Quantitative Full Spectrum Analysis Instrument Spark Direct Reading Spectrometers
  • Drawell Dw-Ty-9000 Metal Quantitative Full Spectrum Analysis Instrument Spark Direct Reading Spectrometers
    Drawell Dw-Ty-9000 Metal Quantitative Full Spectrum Analysis Instrument Spark Direct Reading Spectrometers
  • Drawell Dw-Ty-9000 Metal Quantitative Full Spectrum Analysis Instrument Spark Direct Reading Spectrometers
    Drawell Dw-Ty-9000 Metal Quantitative Full Spectrum Analysis Instrument Spark Direct Reading Spectrometers
  • Drawell Dw-Ty-9000 Metal Quantitative Full Spectrum Analysis Instrument Spark Direct Reading Spectrometers
    Drawell Dw-Ty-9000 Metal Quantitative Full Spectrum Analysis Instrument Spark Direct Reading Spectrometers

Find Similar Products

Product Description

DW-TY-9000 Type Full Spectrum Direct Reading Spectrometer
Product Description

 General principles

The buyer is responsible for providing the conditions and requirements of the site, and meet the requirements of the external installation and other cooperation conditions, the Seller shall provide the equipment and technical services in accordance with the requirements of this agreement. The seller (to ensure full compliance) shall comply with the requirements of the technical specifications, and the analytical instrument shall meet the requirements of the national (or industry) standards.

DW-TY-9000 Full Spectrum Direct Reading Spectrometer, which adopts the international standards of design and manufacturing technology, follows the steps of international spectrum technology and applied the new all digital technology instead of PMT simulation technology. In addition, in order to make this apparatus' best capability, long term stability and repeability, and the lowest sense lines. The design of vacuum optics room and the technology of all digital excitation light source, advanced CCD detector, high-speed data reading system are applied. This machine is available in metal manufacture and processing industries. It's also one of   the main testing machine in metal metallurgy. Such as quality monitoring, material grade identification, material research and development.

 

Technical configuration

Specifications and technical parameters

Item Index
Detection of substrate Fe,Al,Cu,Ni,Ti,Co,Zn,Sn,Mg,Pb etc
Testing time According to the sample type, generally about 25s
Optical system The Paschen Runge construction full vaccum type optics system
Wavelength coverage 130~800nm
Focal length 400mm
Detector High-performance CCD Array
Electrode Tungsten material injection electrode
Analytical gap The sample analysis of clearance: 3.4mm
Operating temperature (10~35)ºC
Storage temperature (0~45)ºC
Operating humidity 20%~80%
Argon purity requirements 99.999%
Argon gas inlet pressure 0.5MPa
Argon flow Stimulate the flow around 3.5L/min,Maintain flow around 0.4L/min
Stimulate the maximum power 400VA
Type of Lamp-house New digital adjustable light, high energy precombustion technology(HEPS)
Discharge frequency 100-1000 Hz
Discharge current Maximum 400A
Excitation aperture 13mm
Vacuum system The vacuum automatic control and monitoring software
Working power supply 220V AC, 50/60Hz, single phase power supply for protective grounding
Instrument size 725*865*550(mm)
Instrument weight 80kg
 

Optical System

1. Par type Paschen-Runge structure full spectrum of the optical system;
2. Maximum wavelength range(160~850)nm;
3. Multiple high-performance CCD detectors;
4. Integration of optical chamber forming, dynamic Romanian archives park installation, resistance to environmental temperature changes;
5. Light vacuum chamber designed to ensure the C, S, P, N to achieve the best performance;
6. Ray room temperature control, constant temperature of 35ºC;
7. Direct MgF2 lens optics technology and materials to ensure the best energy C, S, P, N ultraviolet wavelengths.
 

Sample excitation station

1. Integrated manifold, injection electrode technology;
2. Optimization of argon gas circuit design ensures effective cooling station excite and motivate metal dust generated in the process effectively into the filter; the sample excitation is more stable, and greatly reduce the body's intake of metal dust, help protect the operator health and safety;
3. Smaller excitation space, argon gas consumption less;
4. Easy to use sample holder;
5. With the function of the electrode electrode should sweep, longer service life, easy cleaning electrode;
6. 13 mm aperture stimulate a more conducive sample analysis;
7. Open sample excitation table can be adapted to a variety of sizes, shapes analyze more samples (with cable);
8. SLR Lens device design, the general staff can facilitate the maintenance of the excitation and lens cleaning.
 

Excitation light source

1. New adjustable digital light source, the highest frequency up to 1000Hz;
2. High energy prediction technology (HEPS);
3. Optimized design of the control and power circuits, improve security features excite;
4. Provide the best analysis for different target spark, an arc or a combination of excitation waveforms;
5. Discharge current: 400 A Max.
 

Excitation light source

1. New adjustable digital light source, the highest frequency up to 1000Hz;
2. High energy prediction technology (HEPS);
3. Optimized design of the control and power circuits, improve security features excite;
4. Provide the best analysis for different target spark, an arc or a combination of excitation waveforms;
5. Discharge current: 400 A Max.
 

Excitation light source

1. New adjustable digital light source, the highest frequency up to 1000Hz;
2. High energy prediction technology (HEPS);
3. Optimized design of the control and power circuits, improve security features excite;
4. Provide the best analysis for different target spark, an arc or a combination of excitation waveforms;
5. Discharge current: 400 A Max.
 

Elements and the scope of instrumental analysis

 
Program  Fe-Low alloy  Fe-Cr-Ni steel   Cr-Ni 
Elements Min Max Min Max
C 0.006 1.3 0.008 2.5
Si 0.01 3.9 0.09 4
Mn 0.03 2.1 0.12 16
P 0.002 0.12 0.003 0.3
S 0.002 0.16 0.001 0.4
Cr 0.01 4.5 7.4 32
Ni 0.004 4.4 0.8 48
Mo 0.004 1.3 0.08 4.2
Al 0.003 1.5 0.005 1.7
Cu 0.002 0.5 0.05 4.5
Co 0.001 0.5 0.008 17
Ti 0.002 1.2 0.005 1.1
Nb 0.002 0.3 0.02 2
V 0.003 0.9 0.02 9.5
W 0.03 2.1 0.002 4.1
Pb 0.003 0.03 0.001 0.02
Mg 0.001 0.14 0.001 0.14
B 0.006 0.02 0.007 0.02
Sn 0.001 0.09 0.003 0.05
Zn 0.002 0.04 0.006 0.08
Sb 0.002 0.02 0.0005 0.022
Fe (Remain) (Remain)
 

Laboratory environment

Environmental Requirements

Instrument shall be placed in a dedicated laboratory, indoor area larger than 10 square meters, and to ensure that surrounding non hazardous, flammable and corrosive gases. Caution: Do not use this instrument placed in the chemical analysis laboratory.
Working temperature: 10ºC ~ 30ºC, within 3 hours at room temperature fluctuation is less than 2ºC, requires laboratory installation of air conditioning.
Storage temperature: 0ºC ~ 45ºC
Relative Humidity: 20% to 80%, for wet areas, to be equipped with a dehumidification machine.
TY-9000 full spectrum of direct-reading spectrometer spectral chamber mounted in the housing having a temperature control device, can work in such an environment range, if beyond the scope of these requirements, service life and measurement accuracy of the instrument will be affected.

Power Requirements

1) Power supply: single-phase 220 ± 20V, 1KVA power supply.
In order to ensure TY-9000 full spectrum direct reading spectrometer normal use, please for the instrument is equipped with a 1kVA single-phase 220V AC voltage regulator parameters.
2) TY-9000 full spectrum of direct-reading spectrometer with protective grounding single-phase power. To ensure reliable instrument, the user must ensure the grid PE protected well grounded and separate from other protected areas of large equipment. If you can not guarantee that PE is well grounded, please prepare a ground instrument separately for grounding resistance of less than 4Ω.
 

Argon requirements

1) Argon purity≥99.999%, oxygen≤2ppm, including the amount of H2O≤5ppm, (argon gas cylinders can not open storage, non-rain). If there is no purity argon gas, argon gas purifier is recommended.
2) The use of argon gas flow rate: standby flow rate of about 0.1L/min, maintaining the flow of about (0.4-0.5) L/min, to stimulate the flow of about 3.5L/min.
3) Argon pressure control: 0.5Mpa.

Argon requirements

1) Argon purity≥99.999%, oxygen≤2ppm, including the amount of H2O≤5ppm, (argon gas cylinders can not open storage, non-rain). If there is no purity argon gas, argon gas purifier is recommended.
2) The use of argon gas flow rate: standby flow rate of about 0.1L/min, maintaining the flow of about (0.4-0.5) L/min, to stimulate the flow of about 3.5L/min.
3) Argon pressure control: 0.5Mpa.

Row of cylinders

Instrument exhaust gas through a 14mm diameter PVC reinforced pipe routed supplied filter bottle. Exhaust bottle should be cleaned in time to prevent poor gas replacement.
 

Sample Preparation

Non-ferrous metal samples for aluminum, copper, etc. must use special lathe sample preparation.
For iron-based samples must use special sample preparation grinding prototype, a prototype mill and a floor-grinding machine for grinding steel sample surface. White cast iron samples must be uniform.
Users need a cutting machine for processing shape suitable for spectrometric analysis of samples.
Samples to be analyzed must be uniform, no holes, no casting defects, preparation must achieve a smooth surface, no oxide layer, no oil, no burr edge of the sample.

Standard sample request

TY-9000 full spectrum of direct-reading spectrometer factory will be bundled with a spectral calibration standards for the overall spectral calibration instrument drift. In addition, users need to prepare for their own internal control standard sample or sample product type, for correcting the instrumental analysis curve.

PC and printer requirements

Prepare a general configuration of the current PC (notebooks and desktops can be), requires more than 1GB memory, CPU dual-core 1.8G Hz or more, for the installation TY-9000 full spectrum of direct-reading spectrometer analysis software.
Prepare a printer, laser, inkjet or dot matrix printer can be used to analyze the data to print the report.
 
Detailed Photos
Drawell Dw-Ty-9000 Metal Quantitative Full Spectrum Analysis Instrument Spark Direct Reading SpectrometersDrawell Dw-Ty-9000 Metal Quantitative Full Spectrum Analysis Instrument Spark Direct Reading SpectrometersDrawell Dw-Ty-9000 Metal Quantitative Full Spectrum Analysis Instrument Spark Direct Reading SpectrometersDrawell Dw-Ty-9000 Metal Quantitative Full Spectrum Analysis Instrument Spark Direct Reading SpectrometersDrawell Dw-Ty-9000 Metal Quantitative Full Spectrum Analysis Instrument Spark Direct Reading SpectrometersDrawell Dw-Ty-9000 Metal Quantitative Full Spectrum Analysis Instrument Spark Direct Reading Spectrometers
 
Certifications

Drawell Dw-Ty-9000 Metal Quantitative Full Spectrum Analysis Instrument Spark Direct Reading SpectrometersDrawell Dw-Ty-9000 Metal Quantitative Full Spectrum Analysis Instrument Spark Direct Reading Spectrometers

FAQ

Drawell Dw-Ty-9000 Metal Quantitative Full Spectrum Analysis Instrument Spark Direct Reading Spectrometers

About the Supplier

This supplier has been audited by SGS. Verify the report on the official SGS website with ID "QIP-ASR2391291". Items marked "verified" are certified.

Watch Video
Watch Video
Chongqing Drawell Instrument Co., Ltd.
Chongqing Drawell Instrument Co., Ltd.
Chongqing Drawell Instrument Co., Ltd.
Chongqing Drawell Instrument Co., Ltd.
Chongqing Drawell Instrument Co., Ltd.
Chongqing Drawell Instrument Co., Ltd.
Chongqing Drawell Instrument Co., Ltd.
Chongqing Drawell Instrument Co., Ltd.

About Our Factory & Business Background

Address
Room 2204, Building 11, No. 1 Shiyou Road, Yuzhong District, Chongqing, China
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram
International Commercial Terms(Incoterms)
FOB, EXW, CFR, CIF, DAT, FAS, DDP, DAP, CIP, CPT, FCA
Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays
Nearest Port
Shanghai, Guangzhou, Shenzhen and etc.

Our Production Capability & Technical Expertise

Main Products
Spectrophotometer/ Spectrometer, Autoclave, PCR, Chromatograph, Freezer, Incubator and Oven, Centrifuge, Microscope, Rotary Evaporator, Balance

Our Industry Experience & Global Business Record

Export Year
2014-03-18
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What is the testing time for the instrument?
Generally about 25 seconds, depending on the sample type.
What is the warranty period?
We provide a 1-year warranty for the instrument.
Is the product customizable?
Yes, the instrument offers customized detection for various substrates such as Fe, Al, Cu, Ni, Ti, Co, Zn, Sn, Mg, Pb, etc.
What is the lead time for delivery?
During peak season, the lead time is one month; during off-season, it is within 15 working days.
What kind of technical support is available?
Online technical support is provided for installation, operation, and maintenance assistance.
What is the wavelength coverage of the spectrometer?
The wavelength coverage is 130-800nm.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now