Customization: | Available |
---|---|
After-sales Service: | Online Technical Support |
Warranty: | 1 Year |
Still deciding? Get samples of US$ 9660/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
DW-GC1290 GC Chromatography
Features:
★Control system: designed for monitoring and controlling the instrument via the computer.
★Column Compartment/oven with superior thermal performance, multistage (20 ramps) programmed temperature control function. (supported by "control system")
★Advanced built-in data acquisition system , supporting real time instrument status monitoring, detection signal acquisition and PC control
★Column oven supports quick heat-up and rapid cool-down with automated back-door opening.
★Flexible sample introduction system: 2 sample injectors could be installed and operated simultaneously with independent temperature control.
★High sensibility and stability detector.
★2 independent and analog signals output.
★M6 software, compatible with GLP/FDA-21 CFR Part11 requirements and regulations. (electronic records and signatures)
Gas chromatography and accessories:
Carrier Gas System + Sample Introduction System + Separation System + Temperature Control System + Detector
Carrier Gas System: air source/ purification and desiccation device/ flow rate control device
Sample Introduction System: sample injector
Separation System: chromatographic column(packed column and capillary column)
Temperature Control System (Column Oven): constant temperature and programmed temperature
Detector: FID/FPD/ NPD
Advanced Microcomputer Control System:
★Superior performance with advanced, microcomputer-based temperature control system
★High temperature accuracy (optimum ± 0.02ºC), high reliability, and anti-interference
★Self-diagnosis/ self-protection function (overheat protection, power-off protection, etc.)
★Intuitive display of timing program, detector status, measurement range, current setting, etc
Model# | GC1290 | ||
Description | EPC(electronic pneumatic control) 7 inch touch screen display |
||
Sample Introduction System | sample injector and evaporation chamber | ||
Column Oven | Temperature range | Ambient temperature +7ºC ~ 420ºC (in 1ºC increment) | |
Temperature accuracy | ± 0.02ºC | ||
Cooling time | 350ºC~100ºC≤3min, 400ºC~50ºC in 8-10 min at 25ºC ambient | ||
Programmed temperature setting | 0.1ºC~80ºC/min (in 1ºC increment) | ||
Program ramps | 20 ramps in total (99 ramps available with control workstation) | ||
Size (L*W*H) | 284*280*241mm(inside) | 340*345*281mm(outside) | |
Flame Ionization Detector (FID) |
Detection limit | ≤8×10-12g/s (n-hexadecane) | |
Drift | ≤1.5×10-13A/h | ||
Noise | ≤3×10-14A | ||
Linearity range | ≥106 | ||
(TCD) Thermal conductivity detector |
Maximum operating temperature | 400 ° C | |
Temperature control accuracy | ± 0.1 ° C | ||
Sensitivity | ≥10000mv • ml / mg (n-hexadecane) | ||
Baseline noise | ≤20uv | ||
Baseline drift | ≤100uv / 30min (after the instrument is stable for 2 hours) | ||
Linear dynamic range | ≥104 | ||
(FPD) Flame Photometric Detector |
Detection limit | ≤8×10‐13g/s(P) ; ≤8×10‐11g/s(S) | |
Drift | ≤2×10‐11A/30min | ||
Baseline noise | ≤5×10‐12A | ||
(NPD) Nitrogen-Phosphorus Detector |
Detection limit | ≤5×10-12g/s(N) (Azobenzene) ≤5×10-13g/s(P) (Malathion) |
|
Electron Capture Detector (ECD) | Detection limit | ≤3×10-14g/ml (γ-666) | |
Drift | ≤ 100 μV/30min | ||
Noise | ≤ 40μV |