• Dw-Gc1120 Laboratory Equipment Chromatography Fid Tcd Fpd Npd Gas Chromatography Instrument
  • Dw-Gc1120 Laboratory Equipment Chromatography Fid Tcd Fpd Npd Gas Chromatography Instrument
  • Dw-Gc1120 Laboratory Equipment Chromatography Fid Tcd Fpd Npd Gas Chromatography Instrument
  • Dw-Gc1120 Laboratory Equipment Chromatography Fid Tcd Fpd Npd Gas Chromatography Instrument
  • Dw-Gc1120 Laboratory Equipment Chromatography Fid Tcd Fpd Npd Gas Chromatography Instrument
  • Dw-Gc1120 Laboratory Equipment Chromatography Fid Tcd Fpd Npd Gas Chromatography Instrument

Dw-Gc1120 Laboratory Equipment Chromatography Fid Tcd Fpd Npd Gas Chromatography Instrument

After-sales Service: Online Service
Warranty: 1year
Appliance: The Analysis of Environmental Samples
Ray Type: /
Gaspath System: /
Detector: /
Samples:
US$ 3355/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2020

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company
  • Overview
  • Product Description
  • Detailed Photos
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
DW-GC1120
Energy Resolution
/
Certification
CE, ISO
Spectrometer Detector
UV
Stationary Phase
Liquid Solvent
Mobile Phase
Liquid
Chromatography Type
Gas Chromatography
Chromatographic Column Type
Capilary Column
Chromatographic Column Length
10~30cm
Chromatographic Column Diameter
1~2mm
Temperature Range
Ambient Temperature +7ºC ~ 400ºC
Temperature Accuracy
± 0.02ºC
Cooling Time
400ºC to 50ºC in 8-10 Min
Programmed Temperature Setting
0.1ºC~40ºC/Min (in 1ºC Increment)
Detection Limit
≤3×10-12g/S (C16)
Best Test Result
≤3×10-12g/S (C16)
Drift
≤6×10-13A/30min
Noise
≤5×10-14A
Linearity Range
≥106
Sensitivity
≥5000mv, Ml/Mg (C16)
Baseline Noise
≤20µV
Detector Drift
≤60µV/H
Detector Linearity Range
≥104
Transport Package
Wooden Box
Specification
83*68*83; 85KGS
Trademark
Drawell
Origin
Chongqing, China
HS Code
9027201200
Production Capacity
100pieces/Month

Product Description

Product Description
   Gas Chromatography 
  
Model#  DW-GC1120
Sample Introduction System sample injector and evaporation chamber
Column Oven Temperature range Ambient temperature +7ºC ~ 400ºC  (in 1ºC increment)
Temperature accuracy  ± 0.02ºC
Cooling time 400ºC to 50ºC in 8-10 min at 25ºC ambient
Programmed temperature setting 0.1ºC~40ºC/min (in 1ºC increment)
Program ramps 7 ramps in total (10 ramps available with control workstation)
Size (L*W*H) 284*280*241mm(inside) 340*345*281mm(outside)
Flame Ionization Detector
(FID)
Detection limit 3×10-12g/s (C16
Best test result 3×10-12g/s (C16)
Drift 6×10-13A/30min
Noise 5×10-14A
Linearity range 106
Thermal Conductivity Detector
(TCD)
Sensitivity ≥5000mV, mL/mg (C16)
Baseline noise 20µV
Drift 60µV/h
Linearity range 104
Flame Photometric Detector
(FPD)
Detection limit 8×10-13g/s(P) ; 8×10-11g/s(S)
Drift 2×10-11A/30min
Baseline noise 5×10-12A
Nitrogen-Phosphorus Detector
(NPD)
Detection limit ≤5×10-12g/s(N)  (Azobenzene)
            ≤5×10-13g/s(P)  (Malathion)
Features:      
Control system: designed for monitoring and controlling the instrument via the computer.
Column Compartment/oven with superior thermal performance, multistage (10 ramps) programmed temperature control function. (supported by "control system")
Advanced built-in data acquisition system , supporting real time instrument status monitoring, detection signal acquisition and PC control
Column oven accommodates up to 3 chromatographic columns, and supports quick heat-up and rapid cool-down with automated back-door opening.
Flexible sample introduction system: 3 sample injectors could be installed and operated simultaneously with independent temperature control.
High sensibility and stability detector.
2 independent and analog signals output.
M6 software, compatible with GLP/FDA-21 CFR Part11 requirements and regulations. (electronic records and signatures)
Gas chromatography and accessories:      
Carrier Gas System + Sample Introduction System + Separation System + Temperature Control System + Detector
Carrier Gas System: air source/ purification and desiccation device/ flow rate control device
Sample Introduction System: sample injector
Separation System: chromatographic column(packed column and capillary column)
Temperature Control System (Column Oven): constant temperature and programmed temperature
Detector: FID/ TCD/ FPD/ NPD
       
Advanced Microcomputer Control System      
Superior performance with advanced, microcomputer-based temperature control system
High temperature accuracy (optimum ± 0.02ºC), high reliability, and anti-interference
Self-diagnosis/ self-protection function (overheat protection, power-off protection, etc.)
Intuitive display of timing program, detector status, measurement range, current setting, etc

 
Detailed Photos

 

Dw-Gc1120 Laboratory Equipment Chromatography Fid Tcd Fpd Npd Gas Chromatography InstrumentDw-Gc1120 Laboratory Equipment Chromatography Fid Tcd Fpd Npd Gas Chromatography InstrumentDw-Gc1120 Laboratory Equipment Chromatography Fid Tcd Fpd Npd Gas Chromatography Instrument

Dw-Gc1120 Laboratory Equipment Chromatography Fid Tcd Fpd Npd Gas Chromatography InstrumentDw-Gc1120 Laboratory Equipment Chromatography Fid Tcd Fpd Npd Gas Chromatography Instrument

Certifications

 

 

Dw-Gc1120 Laboratory Equipment Chromatography Fid Tcd Fpd Npd Gas Chromatography InstrumentDw-Gc1120 Laboratory Equipment Chromatography Fid Tcd Fpd Npd Gas Chromatography Instrument

 

FAQ

 

Dw-Gc1120 Laboratory Equipment Chromatography Fid Tcd Fpd Npd Gas Chromatography Instrument

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2020

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company
Management System Certification
ISO 9001
Export Year
2014-03-18