• Dw-320 190-900nm Chemistry Laboratory Meltallurgy Elements Testing Flame Atomic Absorption Spectrophotometer Aas Machine Aas Analyzer
  • Dw-320 190-900nm Chemistry Laboratory Meltallurgy Elements Testing Flame Atomic Absorption Spectrophotometer Aas Machine Aas Analyzer
  • Dw-320 190-900nm Chemistry Laboratory Meltallurgy Elements Testing Flame Atomic Absorption Spectrophotometer Aas Machine Aas Analyzer
  • Dw-320 190-900nm Chemistry Laboratory Meltallurgy Elements Testing Flame Atomic Absorption Spectrophotometer Aas Machine Aas Analyzer
  • Dw-320 190-900nm Chemistry Laboratory Meltallurgy Elements Testing Flame Atomic Absorption Spectrophotometer Aas Machine Aas Analyzer
  • Dw-320 190-900nm Chemistry Laboratory Meltallurgy Elements Testing Flame Atomic Absorption Spectrophotometer Aas Machine Aas Analyzer

Dw-320 190-900nm Chemistry Laboratory Meltallurgy Elements Testing Flame Atomic Absorption Spectrophotometer Aas Machine Aas Analyzer

After-sales Service: Yes
Application: Laboratory Apparatus
Warranty: 1 Year
Detection Method: Spectrophotometer
Advantage: High Sensitive
Principle: Classic Spectrometer
Samples:
US$ 8000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2020

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
DW-320
Wavelengths
UV Spectrometer
Dispersive Element
/
Light Number
/
Certification
ISO9001, CE
Customized
Customized
Wl Range (Nm)
190-900
Wl Accuracy
±0.5nm
Baseline Stability
0.005A/30min
Background Correction
The D2 Lamp Background Correction Capability at 1A
Monochomator
Single Beam, Czerny-Turner Design Grating Monochro
Grating
1800 L/mm
Focal Length
277mm
Blazed Wavelength
250nm
Spectral Bandwidth
0.1nm, 0.2nm, 0.4nm, 1.2nm 4 Steps
Adjustment
Manual Adjustment for Wavelength and Slit
Burner
10cm Single Slot All-Titanium Burner
Spray Chamber
Corrosion Resistant All-Plastic Spray Chamber.
Nebulizer
High Efficiency Glass Nebulizer with Metal Sleeve,
Position Adjustment
Manual Adjusting Mechanism for Vertical, Horizonta
Gas Line Protection
Fuel Gas Leakage Alarm
Transport Package
Paper
Specification
1220x770x730mm (Main instrument) 800x400x900mm (
Trademark
Drawell
Origin
Chongqing, China
HS Code
9027300000
Production Capacity
100pieces/Month

Product Description

Flame Atomic Absorption Spectrophotometer
DW-320

FEATURES
High cost-effective flame AAS
Reasonable design, adopting the same key parts as in high end instruments, ensures basic functions but less automation to provide an economic model for users

Reliable integration of main unit with microprocessor
Built-in microprocessor with necessary auto-control and data processing functions achieve high reliability of the instrument.

Simple and East Operation
Eye-catching digital display, multi-function data processing ability and fast function-key direct input realize easy and fast analysis.

 

Specifications

Main Specification
Wavelength range 190-900nm
  Wavelength accuracy ±0.5nm
  Resolution Two spectral lines of Mn at 279.5nm and 279.8nm can be separated with the spectral bandwidth of 0.2nm and valley-peak energy ratio less than 30%.
  Baseline stability 0.005A/30min
  Background correction The D2 lamp background correction capability at 1A is better than 30 times.   
Light Source System 2 lamps are powered simultaneously (one preheating)
  Lamp current adjustment range:  0~20mA,                               
  Lamp power supply mode Powered by 400Hz square pulse
Optical System Monochomator Single beam, Czerny-Turner design grating monochromator
  Grating 1800 l/mm
  Focal length 277mm
  Blazed Wavelength 250nm
  Spectral Bandwidth 0.1nm, 0.2nm, 0.4nm, 1.2nm 4 steps
  Adjustment Manual adjustment for wavelength and slit
Flame Atomizer Burner 10cm single slot all-titanium burner    
  Spray chamber Corrosion resistant all-plastic spray chamber.
  Nebulizer High efficiency glass nebulizer with metal sleeve, sucking up rate: 6-7mL/min
  Position adjustment Manual adjusting mechanism for vertical, horizontal positions and the rotation angle of the burner
  Gas line protection Fuel gas leakage alarm
Detection and Data Processing System Detector R928 Photomultiplier with high sensitivity and wide spectral range.
  Electronic and micro-computer system Automatic adjustment of light source power. Light energy and negative high-voltage auto-balance
  Display mode LED display of energy and measurement values, concentration direct reading
  Read mode Transient, time average, peak height, peak area.
Integral time is selectable in the range of 0.1-19.9s.
  Scale expansion 0.1~99
  Data processing mode Automatic calculation of mean, standard deviation and relative standard deviation. Repeating  number is in the rang of 1-99
  Measurement mode Automatic curve fitting with 3~7 standards;  Sensitivity auto-correction
  Result printing Measurement data, working curve, signal profile and analytical conditions can all be printed out.
  Instrument self-check Check current status of each function key
Characteristic Concentration and Detection Limit Air-C2H2 flame Cu: Characteristic concentration≤0.025mg/L, Detection limit≤0.006mg/L;
Function Expansion Hydride vapor generator can be connected for hydride analysis.
Dimensions and Weight 1020 x 490 x 540 mm, 80kg unpacked
 Dw-320 190-900nm Chemistry Laboratory Meltallurgy Elements Testing Flame Atomic Absorption Spectrophotometer Aas Machine Aas AnalyzerDw-320 190-900nm Chemistry Laboratory Meltallurgy Elements Testing Flame Atomic Absorption Spectrophotometer Aas Machine Aas Analyzer

Dw-320 190-900nm Chemistry Laboratory Meltallurgy Elements Testing Flame Atomic Absorption Spectrophotometer Aas Machine Aas Analyzer
Dw-320 190-900nm Chemistry Laboratory Meltallurgy Elements Testing Flame Atomic Absorption Spectrophotometer Aas Machine Aas AnalyzerDw-320 190-900nm Chemistry Laboratory Meltallurgy Elements Testing Flame Atomic Absorption Spectrophotometer Aas Machine Aas AnalyzerDw-320 190-900nm Chemistry Laboratory Meltallurgy Elements Testing Flame Atomic Absorption Spectrophotometer Aas Machine Aas Analyzer

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2020

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company
Management System Certification
ISO 9001
Export Year